TMC603 DATA SHEET (V. 1.06 / 26. Mar. 2009)
18
Pull-up resistor can be
internal to microcontroller
+VCC
TMC603 error logic
Drive with open drain
undervoltage VLS
100k
output, if feedback is
undervoltage VCP
provided
ENABLE
/ERR_OUT
D
D
S: priority
short to GND 1
short to GND 2
short to GND 3
S
R
Q
Q
CLR_ERR
D
GND
Feedback connection for automatic self-protection
figure 13: error logic
Pin
Comments
Error output (open drain). Signals undervoltage or overcurrent. Tie to ENABLE for
/ERR_OUT
direct self protection of the driver. The internal error condition generator has a higher
priority than the CLR_ERR input, i.e. the error condition can not be cleared, as long as
it is persistent.
CLR_ERR
ENABLE
Reset of error flip-flop (active high). Clears error condition. The error condition should
at least be cleared once after IC power on.
Enables the power drivers (low: all MOSFETs become actively switched off)
Copyright © 2008 TRINAMIC Motion Control GmbH & Co. KG