17  
3.3 MOSFETs and Slope Control  
The TMC5161 integrates a discrete MOSFET power stage in order to yield a complete driver. The  
MOSFET driver stage allows adaptation of parameters like gate driver current and blank time, in order  
to optimally fit the driver with the MOSFETs for the given application. The tiny internal driver stage  
operates at 10ns slope with minimum gate driver current setting, which is absolutely sufficient for  
minimum power dissipation. Due to the fast slopes, minimum BBM time setting is sufficient.  
V12VOUT  
Miller plateau  
Lx  
0V  
VVM  
Output  
slope  
Output  
slope  
BMx  
0V  
-1.2V  
VVM+V12VOUT  
VVM  
Hx  
0V  
VCX-VBMx  
Miller plateau  
Hx-  
BMx  
0V  
tBBM  
Effective break-before-make time  
tBBM  
tBBM  
Load pulling BMx down  
Figure 3.3 Slopes, Miller plateau and blank time  
Load pulling BMx up  
The following DRV_CONF parameters allow adapting the driver to the MOSFET bridge:  
Parameter  
Description  
Setting Comment  
BBMTIME  
Break-before-make time setting to ensure non- 0…8  
overlapping switching of high-side and low-side  
MOSFETs. BBMTIME allows fine tuning of times in  
increments shorter than a clock period.  
time[ns]  
100ns*32/(32-BBMTIME)  
Ensure ~30% headroom  
Reset Default: 0  
As the TMC5161 switches very fast, a setting of 0  
is sufficient.  
BBMCLKS  
Like BBMTIME, but in multiple of a clock cycle.  
The longer setting rules (BBMTIME vs. BBMCLKS).  
0 to 2 recommended.  
0…15  
0: off, use BBMTIME  
Reset Default: OTP 4 or 2  
As the TMC5161 switches very fast, a setting of 0  
is sufficient. However, there is only negligible  
difference with settings 2 or 4.  
DRV_  
STRENGTH  
Selection of gate driver current. Higher settings 0…2  
give faster slopes. 0 recommended.  
Reset Default = 2  
0 recommended.  
00: ~100ns (reset default)  
01: ~200ns  
10: ~300ns  
11: ~400ns  
FILT_ISENSE Filter time constant of sense amplifier to suppress 0…3  
ringing and coupling from second coil operation  
Hint: Increase setting if motor chopper noise  
occurs due to cross-coupling of both coils.  
(Reset Default = %00)  