TMC4330A Datasheet | Document Revision 1.01 2017-JAN-12  
35/166  
Start Velocity VSTART and Stop Velocity VSTOP  
S-shaped and trapezoidal velocity ramps can be configured with unsigned start and stop  
velocity values: VSTART, or VSTOP.  
Per default, VSTART and VSTOP are set to 0. The sign is selected automatically,  
depending on the current ramp status and the target velocity, or target position. This section  
explains how to set up the respective values correctly.  
Starting Ramps  
with initial  
Velocity  
S-shaped and trapezoidal velocity ramps can be started with an initial velocity value,  
if you set the VSTART value higher than zero (see Figure below).  
In order to use trapezoidal ramps with an initial start velocity, do as follows:  
Action:  
Set RAMPMODE(1:0)=b’01 (register 0x20).  
Set Trapezoidal ramp type accordingly, as explained before.  
Set proper VSTART > 0 (register 0x25).  
Set VSTOP = 0 (register 0x26).  
Result:  
The trapezoidal ramp starts with initial velocity.  
NOTE:  
The initial acceleration value is AMAX if VBREAK < VSTART, otherwise the starting  
acceleration value is ASTART.  
v(t)  
A1L A1 A2 A3 A3L  
VMAX  
VBREAK  
VSTART  
t
Figure 22: Trapezoidal Ramp with initial Velocity  
If trapezoidal ramp with initial velocity VSTART is selected:  
Avoid unintended system behavior during positioning mode!  
NOTICE  
Use VSTART without setting VSTOP > VSTART only in positioning mode if there  
is enough distance between the current position XACTUAL and the target  
position XTARGET.  
This will ensure smooth operation during positioning mode.  
Turn page for information on how to configure S-shaped ramps with initial start  
velocity.  
© 2015 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany Terms of delivery and rights  
to technical change reserved. Download newest version at: www.trinamic.com .  
Read entire documentation; especially the Supplemental Directiveson page 160.  
MAIN MANUAL   
 