TMC262 DATASHEET (Rev. 2.07 / 2013-FEB-14)  
40  
11 Diagnostics and Protection  
11.1 Short to GND Detection  
The short to ground detection prevents the high-side power MOSFETs from being damaged by  
accidentally shorting the motor outputs to ground. It disables the MOSFETs only if a short condition  
persists. A temporary event like an ESD event could look like a short, but these events are filtered out  
by requiring the event to persist.  
When a short is detected, the bridge is switched off immediately, the chopper cycle on the affected  
coil is terminated, and the short counter is incremented. The counter is decremented for each phase  
polarity change. The MOSFETs are shut off when the counter reaches 3 and remain shut off until the  
short condition is cleared by disabling the driver and re-enabling it.  
The short to ground detection status is indicated by two bits:  
Status  
Description  
Range  
Comment  
S2GA  
S2GB  
These bits identify a short to GND condition on 0 / 1  
coil A and coil B persisting for multiple chopper  
cycles. The bits are cleared when the MOSFETs  
are disabled.  
0: No short  
condition  
detected.  
1: Short condition  
detected.  
An overload condition on the high-side MOSFET (“short to GND”) is detected by monitoring the coil  
voltage during the high-side on phase. Under normal conditions, the high-side power MOSFET reaches  
the bridge supply voltage minus a small voltage drop during the on phase. If the bridge is  
overloaded, the voltage cannot rise to the detection level within the time defined by the internal  
detection delay setting. When an overload is detected, the bridge is switched off. The short to GND  
detection delay needs to be adjusted for the slope time, because it must be longer than slope, but  
should not be unnecessarily long.  
Hxy  
0V  
VVS  
VVS-  
VBMS2G  
Short to GND  
detected  
Valid area  
BMxy  
Short  
detection  
0V  
0V  
Driver off  
Driver  
enabled  
tS2G  
tS2G  
Short to GND  
monitor phase  
BM voltage  
monitored  
inactive delay  
inactive  
delay  
Short detected  
Figure 11.1 Short to GND detection timing  