5 Functional Description  
5.1 Position Controller and Main Controller  
5.1.1 Stepping Modes  
The TMC211 supports up to 16 micro steps per full step, which leads to smooth and low torque ripple  
motion of the stepping motor. Four stepping modes (micro step resolutions) are selectable by the user:  
See also 5.3 Stepper Motor Driver on page 21.  
Half step Mode  
1/4 Micro stepping  
1/8 Micro stepping  
1/16 Micro stepping  
5.1.2 Velocity Ramp  
A common velocity ramp where a motor drives to a desired position is shown in the figure below. The  
motion consists of an acceleration phase, a phase of constant speed and a final deceleration phase.  
Both the acceleration and the deceleration are symmetrical. The acceleration factor can be chosen  
from a table with 16 entries. (Table 5: Acc Parameter on page 11). A typical motion begins with a start  
velocity Vmin. During acceleration phase the velocity is increased until Vmax is reached. After  
acceleration phase the motion is continued with velocity Vmax until the velocity has to be decreased in  
order to stop at the desired target position. Both velocity parameters Vmin and Vmax are  
programmable, whereas Vmin is a programmable ratio of Vmax (see Table 3: Vmax Parameter on  
page 10 and Table 4: Vmin on page 11). The user has to take into account that Vmin is not allowed to  
change while a motion is ongoing. Vmax is only allowed to change under special circumstances. (See  
5.1.4 Vmax Parameter on page 10).  
The peak current value to be fed to each coil of the stepper-motor is selectable from a table with 16  
possible values. It has to be distinguished between the run current Irun and the hold current Ihold. Irun  
is fed through the stepper motor coils while a motion is performed, whereas Ihold is the current to hold  
the stepper motor before or after a motion. More details about Irun and Ihold can be found in 5.3.1 and  
5.3.2.  
Velocity resp. acceleration parameters are accessable via the LIN interface. These parameters are  
written via the SetMotorParam command (See Page 42) and read via the GetFullStatus command  
(See Page 36).  
Velocity V  
[FS/s]  
Vmax  
Vmin  
time  
[s]  
Xstart  
Xtarget  
No  
Acceleration  
Phase  
Deceleration  
Phase  
No  
State of Motion  
Movement  
Constant Velocity  
Movement  