欢迎访问ic37.com |
会员登录 免费注册
发布采购

TMC2160-TA 参数 Datasheet PDF下载

TMC2160-TA图片预览
型号: TMC2160-TA
PDF下载: 下载PDF文件 查看货源
内容描述: [Universal high voltage driver for two-phase bipolar stepper motor.]
分类和应用:
文件页数/大小: 107 页 / 2580 K
品牌: TRINAMIC [ TRINAMIC MOTION CONTROL GMBH & CO. KG. ]
 浏览型号TMC2160-TA的Datasheet PDF文件第74页浏览型号TMC2160-TA的Datasheet PDF文件第75页浏览型号TMC2160-TA的Datasheet PDF文件第76页浏览型号TMC2160-TA的Datasheet PDF文件第77页浏览型号TMC2160-TA的Datasheet PDF文件第79页浏览型号TMC2160-TA的Datasheet PDF文件第80页浏览型号TMC2160-TA的Datasheet PDF文件第81页浏览型号TMC2160-TA的Datasheet PDF文件第82页  
TMC2160 DATASHEET (Rev. 1.02 / 2018-NOV-19)  
78  
14 DIAG Outputs  
Operation with an external motion controller often requires quick reaction to certain states of the  
stepper motor driver. Therefore, the DIAG outputs supply a configurable set of different real time  
information complementing the STEP/DIR interface.  
Both, the information available at DIAG0 and DIAG1 can be selected as well as the type of output  
(low active open drain default setting, or high active push-pull). In order to determine a reset of the  
driver, DIAG0 always shows a power-on reset condition by pulling low during a reset condition.  
Figure 14.1 shows the available signals and control bits.  
Power-on reset  
Driver error  
diag0_pushpull  
diag0_error  
PMD  
DIAG0  
Overtemp. prewarning  
diag0_otpw  
Stall  
diag0_stall  
PDD=100k pulldown  
PMD=50k to VCC/2  
diag1_stall  
Sequencer microstep 0 index  
diag1_pushpull  
diag1_index  
PDD  
DIAG1  
Chopper on-state  
diag1_onstate  
dcStep steps skipped  
diag1_steps_skipped  
Figure 14.1 DIAG outputs  
The stall output signal allows stallGuard2 to be handled by the external motion controller like a stop  
switch. The index output signals the microstep counter zero position, to allow the application to  
reference the drive to a certain current pattern. Chopper on-state shows the on-state of both coil  
choppers (alternating) when working in spreadCycle or constant off time in order to determine the  
duty cycle. The dcStep skipped information is an alternative way to find out when dcStep runs with a  
velocity below the step velocity. It toggles with each step not taken by the sequencer.  
Attention  
The duration of the index pulse corresponds to the duration of the microstep. When working without  
interpolation at less than 256 microsteps, the index time goes down to two CLK clock cycles.  
www.trinamic.com  
 
 复制成功!