TMC2100 DATASHEET (Rev. 1.07 / 2017-MAY-15)
37
Linear regulator
DC-Characteristics
VVS = VVSA = 24.0V
Parameter
Symbol Conditions
Min
Typ
Max Unit
Output voltage
V5VOUT
I5VOUT = 0mA
TJ = 25°C
4.80
5.0
5.25
V
Output resistance
R5VOUT
Static load
3
Deviation of output voltage over V5VOUT(DEV) I5VOUT = 16mA
the full temperature range
+/-30
+/-100
+/-30
+/-75
mV
TJ = full range
Deviation of output voltage over V5VOUT(DEV) I5VOUT = 0mA
the full supply voltage range
+/-15
-38
mV /
10V
VVSA = variable
Deviation of output voltage over V5VOUT(DEV) I5VOUT = 16mA
mV /
10V
the full supply voltage range
VVSA = variable
Clock oscillator and input
Parameter
Clock oscillator frequency
Clock oscillator frequency
Clock oscillator frequency
External clock frequency
(operating)
Timing-Characteristics
Symbol Conditions
Min
9
10.1
Typ
12.4
13.2
13.4
10-16
Max Unit
MHz
fCLKOSC
fCLKOSC
fCLKOSC
fCLK
tJ=-50°C
tJ=50°C
tJ=150°C
17.2
18
MHz
MHz
MHz
4
18
External clock high / low level
time
External clock first cycle
triggering switching to external
clock source
tCLKH
tCLKL
tCLKH1
/
CLK driven to
0.1 VVIO / 0.9 VVIO
CLK driven high
10
30
ns
ns
25
Detector levels
Parameter
DC-Characteristics
Symbol Conditions
Min
Typ
Max Unit
VVSA undervoltage threshold for
RESET
VUV_VSA
VVSA rising
3.8
4.2
4.6
V
V5VOUT undervoltage threshold for VUV_5VOUT
RESET
VVCC_IO undervoltage threshold for VUV_VIO
RESET
V5VOUT rising
3.5
2.55
0.3
V
VVCC_IO rising (delay
typ. 10µs)
2.1
3.0
V
VVCC_IO undervoltage detector
hysteresis
VUV_VIOHYST
V
Short to GND detector threshold VOS2G
(VVS - VOx)
2
2.5
3
2
V
Short to GND detector delay
(high side switch on to short
detected)
tS2G
High side output
clamped to VVS-3V
0.8
1.3
µs
Overtemperature recovery
Overtemperature shutdown
tOTPW
tOT
Temperature falling
Temperature rising
100
135
120
150
140
170
°C
°C
www.trinamic.com