TMC2100 DATASHEET (Rev. 1.07 / 2017-MAY-15)
36
15.2 DC and Timing Characteristics
DC characteristics contain the spread of values guaranteed within the specified supply voltage range
unless otherwise specified. Typical values represent the average value of all parts measured at +25°C.
Temperature variation also causes stray to some values. A device with typical values will not leave
Min/Max range within the full temperature range.
Power supply current
DC-Characteristics
VVS = VVSA = 24.0V
Parameter
Symbol Conditions
Min
Typ
Max Unit
Total supply current, driver
disabled IVS + IVSA + IVCC
IS
fCLK=16MHz
15
22
mA
Total supply current, operating,
IVS + IVSA + IVCC
Idle supply current from VS,
charge pump operating
Static supply current from VSA
with VCC supplied by 5VOUT
Supply current, driver disabled,
dependency on CLK frequency
Internal current consumption
from 5V supply on VCC pin
IO supply current (typ. at 5V)
IS
fCLK=16MHz, 23.4kHz
chopper, no load
fCLK=0Hz,
driver disabled
fCLK=0Hz, includes
VCC supply current
fCLK variable,
additional to IVSA0
fCLK=16MHz, 23.4kHz
chopper
no load on outputs,
inputs at VIO or GND
Excludes pullup /
pull-down resistors
19
0.25
2
mA
mA
IVS0
IVSA0
IVCCx
IVCC
IVIO
0.5
3
1.4
mA
mA/MHz
0.8
16
mA
µA
15
30
Motor driver section
DC- and Timing-Characteristics
VVS = 24.0V
Parameter
Symbol Conditions
Min
Typ
Max Unit
RDSON lowside MOSFET
RONL
measure at 100mA,
25°C, static state
measure at 100mA,
25°C, static state
measured at 700mA
load current
(resistive load)
measured at 700mA
load current
0.4
0.5
Ω
RDSON highside MOSFET
slope, MOSFET turning on
RONH
tSLPON
0.5
0.6
Ω
50
50
120
220
ns
slope, MOSFET turning off
tSLPOFF
120
180
220
250
ns
(resistive load)
OXX pulled to GND
Current sourcing, driver off
IOIDLE
120
µA
Charge pump
DC-Characteristics
Parameter
Symbol Conditions
Min
Typ
Max Unit
Charge pump output voltage
VVCP-VVS
VVCP-VVS
fCP
operating, typical
fchop<40kHz
using internal 5V
regulator voltage
4.0
VVCC
0.3
3.6
-
VVCC
V
Charge pump voltage threshold
for undervoltage detection
Charge pump frequency
3.3
3.8
V
1/16
fCLKOSC
www.trinamic.com