Electrical Specifications (@25C)
1. Maximum Power: 50.0VA
2. Input Voltage –
Series:
230VAC @ 50/60Hz,
Parallel:
115VAC@ 50/60Hz
3. Output Voltage –
Series:
12.6V CT@ 3.97A,
Parallel:
6.3V CT @ 7.94A
4. Voltage Regulation: 20% TYP @ full load to no load
5. Hipot: 3500VAC between primary to secondary and windings to core.
Dual winding construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements. Shrouds are provided over the
connections of the leads to the windings on both primary and secondary coils. Devices are
designed with a minimum of 6mm creepage distance between the primary and secondary
and are manufactured with a Class B (130°C) insulation system.
A
BLK
WHT
BRN
BLU
Construction:
E
Agency Files:
GRY
YEL
ORN
RED/YEL
VIO
RED
B
D
TUV Certificate No.: R72103639, EN60950, Information Technology
Dimensions:
A
2.562
B
4.00
C
2.250
D
3.562
Units: In inches
E
8.00
F
0.187
C
F
Weight: 2.3 lbs.
Connections
1
:
Input:
Series – BLK to BLU, Jumper WHT to BRN
Parallel – BLK to BLU, Jumper BLK to BRN and WHT to BLU
Output:
Series – RED to GRY, Jumper YEL to VIO
Parallel – RED to GRY, Jumper RED to VIO and YEL to GRY
BLK
RED
RED/YEL
WHT
BRN
YEL
VIO
ORN
RoHS Compliance:
As of manufacturing date February 2005, all standard products meet the
requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
1
BLU
GRY
Primary and secondary windings are designed to be connected in series or parallel. Winding are not
intended to be used independently.
SCHEMATIC
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013