Triad Magnetics Product Details
FP230-10
FP10-600
FP12-475
FP16-375
FP20-300
FP24-250
FP30-200
FP34-170
FP40-150
FP56-100
FP88-65
2.5 230.0V CT @ 0.01A 115.0V @ 0.02A 0.650 1.562 1.875 1.600 0.375
5
6.0 10.0V CT @ 0.6A
5.0V @ 1.2A
0.875 1.562 1.875 1.600 0.375
0.875 1.562 1.875 1.600 0.375
0.875 1.562 1.875 1.600 0.375
0.875 1.562 1.875 1.600 0.375
0.875 1.562 1.875 1.600 0.375
0.875 1.562 1.875 1.600 0.375
7
6.0 12.6V CT @ 0.475A 6.3V @ 0.95A
6.0 16.0V CT @ 0.375A 8.0V @ 0.75A
7
7
6.0 20.0V CT @ 0.3A
6.0 24.0V CT @ 0.25A
6.0 30.0V CT @ 0.2A
6.0 34.0V CT @ 0.17A
6.0 40.0V CT @ 0.15A
6.0 56.0V CT @ 0.1A
10.0V @ 0.6A
12.0V @ 0.5A
15.0V @ 0.4A
7
7
7
17.0V @ 0.34A 0.875 1.562 1.875 1.600 0.375
7
20.0V @ 0.3A
28.0V @ 0.2A
0.875 1.562 1.875 1.600 0.375
0.875 1.562 1.875 1.600 0.375
7
7
7
6.0 88.0V CT @ 0.065A 44.0V @ 0.13A 0.875 1.562 1.875 1.600 0.375
6.0 120.0V CT @ 0.05A 60.0V @ 0.1A 0.875 1.562 1.875 1.600 0.375
6.0 230.0V CT @ 0.025A 115.0V @ 0.05A 0.875 1.562 1.875 1.600 0.375
FP120-50
FP230-25
7
7
FP10-1200 12.0 10.0V CT @ 1.2A
FP12-950 12.0 12.6V CT @ 0.95A
FP16-750 12.0 16.0V CT @ 0.75A
FP20-600 12.0 20.0V CT @ 0.6A
FP24-500 12.0 24.0V CT @ 0.5A
FP30-400 12.0 30.0V CT @ 0.4A
FP34-340 12.0 34.0V CT @ 0.34A
FP40-300 12.0 40.0V CT @ 0.3A
FP56-200 12.0 56.0V CT @ 0.2A
FP88-130 12.0 88.0V CT @ 0.13A
FP120-100 12.0 120.0V CT @ 0.1A
5.0V @ 2.4A
6.3V @ 1.9A
8.0V @ 1.5A
10.0V @ 1.2A
12.0V @ 1.0A
15.0V @ 0.8A
1.062 2.000 2.500 2.000 0.500 11
1.062 2.000 2.500 2.000 0.500 11
1.062 2.000 2.500 2.000 0.500 11
1.062 2.000 2.500 2.000 0.500 11
1.062 2.000 2.500 2.000 0.500 11
1.062 2.000 2.500 2.000 0.500 11
17.0V @ 0.68A 1.062 2.000 2.500 2.000 0.500 11
20.0V @ 0.6A
28.0V @ 0.4A
1.062 2.000 2.500 2.000 0.500 11
1.062 2.000 2.500 2.000 0.500 11
44.0V @ 0.26A 1.062 2.000 2.500 2.000 0.500 11
60.0V @ 0.2A 1.062 2.000 2.500 2.000 0.500 11
FP230-50 12.0 230.0V CT @ 0.05A 115.0V @ 0.1A 1.062 2.000 2.500 2.000 0.500 11
CT=Center Tap
Technical Notes:
1. H-pot tested at 2,000 VRMS.
2. Split bobbin with side-by-side windings to reduce capacitance and eliminate the need
for a static shield.
Click to Enlarge
http://www.triadmagnetics.com/Catalog/subcategory/ptfp.html (2 of 3)02/03/2005 01:25:25 ã