Industrial Power Supplies
TCL Series
Input Specifications
Input voltage range
output derating at operation between 85...93VAC/85...130VDC:
85...264 VAC / 85...375 VDC
15% for TCL 060 & TCL 120 models
20% for TCL 024-112 & TCL 024-124
30% for TCL 024-105
47 – 63 Hz
EN610000-3-2 Class A
115 VAC
TCL 24 models:
0.35 A
TCL 60 models:
1.2 A
TCL 120 models:
2.0 A
5.0 A
5.1 VDC model:
12 VDC models:
24 VDC models:
48 VDC models:
5.0 – 5.25 VDC
12 – 15 VDC
(12 - 16 VDC for TCL 024-112)
24 – 28 VDC
48 – 56 VDC
2.5% (1% for TCL 60-112)
< 50 mV pk-pk
current limitation at 120 % typ
(constant current, automatic recovery
TCL 24 models: foldback, automatic recovery)
output current characteristic suitable for
parallel operation of max. 5 units
5.1 VDC model:
< 6.5 VDC
12 / 24 VDC models:
< 40 VDC
48 VDC models:
< 60 VDC
115 VAC
min. 15 ms
trigger
point
12 VDC models:
>11V
24 VDC models:
>22V
48 VDC models:
>44V
230 VAC
min. 125 ms
output signal
(reference to – Vout)
11.0 V ±1.0V / 60 mA max.
22.0 V ±2.0V / 30 mA max.
44.0 V ±4.0V / 15 mA max.
230 VAC
0.2 A
0.6 A
1.0 A
24–120 Watt
Input frequency
Harmonic limits
Input current at full load (typ.)
Recommended circuit breaker
(characteristic C or slow blow fuse)
Output Specifications
Output voltage adj. range
(pot.meter on frontpanel)
Output regulation
(10 to 90% load variation)
Ripple and Noise
(20MHz Bandwidth)
Electronic short circuit protection
Parallel operation
Overvoltage protection, triggerpoint
Hold-up time
Power good signal
(TCL 60 & TCL 120 only)
General Specifications
Temperature ranges
Temperature derating
– Operating
– Storage (non operating)
at 187
...264 VAC or 265...375 VDC operation
at 93...132 VAC or 130...187 VDC operation
at 85...130 VDC operation
– 10 °C…+70 °C max.
– 25 °C…+85 °C
1.7% /K above 50°C
1.1% /K above 40°C
1.3% /K above 30°C
95 % rel. H max.
0.02 % /K
55 – 180 kHz
depending on load
(frequency modulation)
88% typ.
according to IEC/EN 60950, UL 60950,
UL 508, EN 50178, EN 60204, EN 61558-2-8
TCL 24 models:
>2.68 Mio h
TCL 60 models:
>2.94 Mio h
TCL 120 models:
>1.62 Mio h
Humidity
(non condensing)
Temperature coefficient
Switching frequency
Efficiency
Isolation
Reliability, calculated MTBF @ 25°C
(according to IEC-1709)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.