Switching Power Supplies
ESP Series
18-150 Watt
General Specifications
Isolation voltage
– Input/ Output
– Input/ Case
– Outpu/ Case
Reliability /calculated MTBF
(MIL-HDBK-217E)
–
ESP 18/ 36/ 60/ 75 (single output)
–
ESP 18/ 36/ 50 /80 (multioutput)
–
ESP 100 / 150
ELectromagnetic compatibility (EMC), Emissions
– Conducted RI suppression
– Harmonic current emissions
ELectromagnetic compatibility (EMC), Immunity
(all single output models)
– Electrostatic discharge ESD
– RF field immunity
– Electrical fast transients/burst immunity
ELectromagnetic compatibility (EMC), Immunity
(all multioutput models)
– Electrostatic discharge ESD
– RF field immunity
– Electrical fast transients/burst immunity
– Surge
Safety standards
Safety approval
IEC / EN 61000-4-2
IEC / EN 61000-4-3
IEC / EN 61000-4-4
IEC / EN 61000-4-2
IEC / EN 61000-4-3
IEC / EN 61000-4-4
IEC / EN 61000-4-5
4 kV / 8 kV
10 mV / m
1 kV
8 kV / 15 kV
10 mV / m
2 kV
1 kV/ 2 kV
EN 55022, class B, FCC part 15, level B
IEC / EN 61000-3-2, class D
equipment
(ESP 50/ 75/ 80/ 100/ 150 only)
> 200‘000 h @ 25°C
> 150’000 h @ 25°C
> 80’000 h @ 25°C
3‘000 VAC
1‘500 VAC
500 VAC
UL 1950, IEC 60950, EN 60950
cUL /UL ( E141988)
(Dual output models and ESP 75/ 100/
150 in process)
Stainless steel
Case material