Switching Power Supplies
ESP Series
18-150 Watt
General Specifications
Isolation voltage
– Input/ Output
– Input/ Case
– Outpu/ Case
Reliability /calculated MTBF
(MIL-HDBK-217E)
–
ESP 18/ 36
–
ESP 60
–
ESP 75/ 100/ 150
ELectromagnetic compatibility (EMC), Emissions
– Conducted RI suppression
– Harmonic current emissions
ELectromagnetic compatibility (EMC), Immunity
(all single output models)
– Electrostatic discharge ESD
– RF field immunity
– Electrical fast transients/burst immunity
– Surge Immunity
– Voltage dips, short int. and voltage variation
Safety standards
Safety approval
Case material
IEC / EN 61000-4-2
IEC / EN 61000-4-3
4 kV / 8 kV
10 V / m
> 200‘000 h @ 25°C
> 170‘000 h @ 25°C
> 90’000 h @ 25°C
EN 55022, class B, FCC part 15, level B
IEC / EN 61000-3-2, class D
equipment
(ESP 75/ 100/ 150 only)
3‘000 VAC
1‘500 VAC
500 VAC
IEC / EN 61000-4-4 1 kV
IEC / EN 61000-4-5 1/2 kV
IEC / EN 61000-4-11
UL 60950, IEC/EN 60950
cUL /UL ( E141988)
stainless steel
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www
.tracopower
.com
Page 4 of 7