欢迎访问ic37.com |
会员登录 免费注册
发布采购

TS1005DB-SOT 参数 Datasheet PDF下载

TS1005DB-SOT图片预览
型号: TS1005DB-SOT
PDF下载: 下载PDF文件 查看货源
内容描述: TS1005运算放大器演示板 [TS1005 Op Amp Demo Board]
分类和应用: 运算放大器
文件页数/大小: 5 页 / 381 K
品牌: TOUCHSTONE [ TOUCHSTONE SEMICONDUCTOR INC ]
 浏览型号TS1005DB-SOT的Datasheet PDF文件第1页浏览型号TS1005DB-SOT的Datasheet PDF文件第3页浏览型号TS1005DB-SOT的Datasheet PDF文件第4页浏览型号TS1005DB-SOT的Datasheet PDF文件第5页  
TS1005 Op Amp Demo Board  
Inverting configuration  
Description  
In an inverting configuration, the circuit’s transfer  
function is given by the following equation:  
The TS1005DB evaluation board with SC70  
packaging provides one configuration, namely an  
inverting configuration. The TS1005DB-SOT  
ꢁ6  
ꢄꢅꢆ = - ꢁ10  
Iꢇ  
evaluation board with SOT23 packaging provides two  
configurations for evaluating the TS1005 operational  
amplifier in one single PCB board, namely a non-  
inverting configuration located on the left-hand side of  
the board and an inverting configuration located on  
the right-hand side of the board. In both cases, the  
input to each circuit is AC-coupled. The demo board  
provides a re-biasing scheme at one-half the power  
supply or VDD/2 for the inverting configuration and at  
VDD/4 for the non-inverting configuration.  
In this case, ꢁ6=1MΩ and ꢁ10=1MΩ. ꢆhis results in  
a signal gain of -1 with a circuit bandwidth of 10kHz  
and an overall circuit bandwidth range of 1.6Hz to  
10kHz.  
Quick Start Procedures  
Required Equipment  
The TS1005 demo board provides a dedicated power  
supply for the non-inverting circuit and a dedicated  
power supply for the inverting circuit. This provides  
the user the flexibility of evaluating one circuit at a  
time or both at the same time.  
TS1005 demo board  
DC Power Supply, Single or Dual Output  
Function Generator  
In both the non-inverting and the inverting  
configuration, the AC-coupling capacitor creates a  
high pass filter. The resulting cut-off frequency, fC, is  
given as:  
4-channel Oscilloscope  
ꢆwo 1MΩ oscilloscope probes  
1
fC=  
2ꢀꢁꢂ  
Non-Inverting Configuration  
In order to evaluate the TS1005 operational amplifier  
in the non-inverting configuration, the following steps  
are to be performed:  
In the non-inverting circuit, ꢁ=ꢁ5=1MΩ and  
ꢂ=ꢂ5=0.1µF. In the inverting case, ꢁ=ꢁ10=1MΩ and  
C=C1=0.1µF. In both cases, these component values  
generate a high-pass cut-off frequency of 1.6Hz.  
1) Before connecting the DC power supply to the  
demo board power test points, turn on the power  
supply and set the DC voltage to 5.5V and then  
turn it off.  
Default Configurations  
Non-Inverting configuration  
In the non-inverting configuration, the circuit’s transfer  
function is given by the following equation:  
2) Set the function generator frequency to 500Hz  
and output level with a VOH = 2.35V and a VOL  
2.15V. This sets the input signal swing to  
200mVPP, centered at 2.25V.  
=
ꢄꢅꢆ  
ꢁꢉ  
ꢁꢊ  
= 1ꢈ  
Iꢇ  
3) In order to monitor the input and output signal,  
select two channels on the oscilloscope and set  
the vertical voltage scale and the vertical position  
on each channel to 100mV/DIV and -2.25V,  
respectively. Set the horizontal time scale to  
500µs/DIV.  
With ꢁꢉ=2MΩ and ꢁꢊ=2MΩ the circuit signal gain is  
2 with a circuit bandwidth of 10kHz. This results in an  
overall circuit bandwidth range of 1.6Hz to 10kHz.  
4) Connect the positive terminal of the DC power  
supply to VDD and the ground terminal to GND.  
Page 2  
TS1005DB r1p1  
RTFDS