DC/DC Converters
THN 30WI Series 30 Watt
Outline Dimensions
Pin-Out
Single
7.62
(0.3)
5.08
(0.2)
Pin
1
Dual
+Vin (Vcc)
+Vin (Vcc)
1
2
6
2
–Vin (GND) –Vin (GND)
Bottom view
4
3
+Vout
Trim
+Vout
Common
–Vout
4
3
5
5
–Vout
10.16 10.16
(0.4)
2.5
(0.1)
5.6
(0.22)
9.9
(0.39)
6
Remote On/Off
(0.4)
25.4
(1.0)
Dimensions in [mm], () = Inch
Pin diameter ø 1.0 (0.04)
Pin pitch tolerances: 0.25 ( 0.01)
Tolerances: 0.5 ( 0.02)
Heat-Sink (Option)
Order code: THN-HS1
(cont.: heat-sink, thermal pad, 2 clamps)
Aluminum
Anodic treatment (black)
8 g (0.28 oz) without converter
Material:
Finish:
Weight:
Thermal impedance after assembling: 13.8 K/W
31.1 (1.22) max.
Heat-sink
Thermal pad
Clamp
Note:
The product label on converter has to be re-
moved before mounting the heat-sink.
For volume orders converters will be sup-
plied with heat-sink already mounted. Please
contact factory for quotation.
Converter
Separate heat-sinks are only available for
prototypes and small quantity orders.
16.5 (0.65)
max.
Specifications can be changed any time without notice.
Rev.
07/12
Specifications can be changed without notice! Make sure you are using the latest documentation, downloadable at www.tracopower.com
www.tracopower.com