DC/DC Converters  
THL 20WI Series  
20 Watt  
Input Specifications  
Input current at no load (at nominal input voltage)  
24 V single output models: 80 mA typ.  
24 V dual output models: 40 mA typ.  
48 V single output models: 40 mA typ.  
48 V dual output models: 25 mA typ.  
Input current at full load (at nominal input voltage)  
24 V; 3.3 VDC models: 700 mA typ.  
24 V; other models: 940 mA typ..  
48 V; 3.3 VDC models: 350 mA typ.  
48 V; other models: 470 mA typ.  
Start-up voltage  
24 V models: 9 VDC (or lower)  
48 V models: 18 VDC (or lower)  
Surge voltage (1 sec. max.)  
Reflected input ripple current  
Conducted noise (input)  
24 Vin models: 50 V max.  
48 Vin models: 100 V max.  
24 V models: 50 mAp-p typ.  
48 V models: 30 mAp-p typ.  
EN 55022 class A, FCC part 15, level A  
with external components (see application note)  
Recommended input fuse (slow blow)  
24 V models: 5000 mA  
48 V models: 2500 mA  
Output Specifications  
Voltage set accuracy  
1 %  
Output voltage adj. range  
10 % for single output models only.  
Trim up via resistor over Trim and -Vout  
Trim down via resistor over Trim and +Vout  
(Resistor values tba, 0 Ohm=max. adjustment)  
Regulation  
– Input variation (Vmin – Vmax) single output models: 0.2 % max.  
dual output models: 0.5 % max.  
– Load variation  
single output models: 0.5 % max. (0 – 100 % load)  
dual output models: 1.0 % max. (8 – 100 % balanced load)  
Minimum load  
single output models: not required  
dual output models: 8 % of rated max current (operation at lower  
load condition will not damage the converters.  
However, they may not meet all listed specifications)  
Ripple and noise (20 MHz bandwidth)  
3.3 & 5.0 VDC models: 75 mVp-p typ.  
12 & 15 VDC models: 100 mVp-p typ.  
24 VDC models: 150 mVp-p typ.  
Measured with a 1µF M/C and a 10µF T/C  
Temperature coefficient  
Output current limitation  
Short circuit protection  
Transient response setting time  
Max. capacitive load  
0.02 %/K  
at 150 % of Iout max., foldback  
indefinite, automatic recovery  
300 µs typ. (25% load step change)  
3.3 VDC models: 10’300 µF  
5 VDC models: 6’800 µF  
12 VDC models: 1’200 µF  
15 VDC models: 750 µF  
24 VDC models: 300 µF  
12 VDC models: 680 µF (each output)  
15 VDC models: 380 µF (each output)  
http://www.tracopower.com  