欢迎访问ic37.com |
会员登录 免费注册
发布采购

THL10-2415WI 参数 Datasheet PDF下载

THL10-2415WI图片预览
型号: THL10-2415WI
PDF下载: 下载PDF文件 查看货源
内容描述: [DC/DC Converters]
分类和应用:
文件页数/大小: 4 页 / 304 K
品牌: TOUCHSTONE [ TOUCHSTONE SEMICONDUCTOR INC ]
 浏览型号THL10-2415WI的Datasheet PDF文件第1页浏览型号THL10-2415WI的Datasheet PDF文件第2页浏览型号THL10-2415WI的Datasheet PDF文件第4页  
DC/DC Converters  
THL 10WI Series  
10 Watt  
General Specifications  
Temperature ranges  
– Operating without heat sink  
– Operating with heat sink  
– Case temperature  
– Storage  
–40°C to +75°C (with derating)  
–40°C to +85°C (with derating)  
+100°C max.  
–40°C to +125°C  
Power derating  
– Operating without heat sink  
– Operating with heat sink  
2.5 %/K above +60°C  
3.5 %/K above +70°C  
Thermal inpedance  
Humidity (non condensing)  
– Natural convection  
– Natural convection with heat sink  
18.2°C/W  
15.8°C/W  
95 % rel H max.  
>350’000 h  
Reliability, calculated MTBF (MIL-HDBK-217F, at +25°C, ground benign)  
Isolation voltage (60 sec.) – Input/Output  
1’500 VDC  
Isolation capacitance  
Isolation resistance  
Remote On/Off  
– Input/Output  
1200 pF max.  
– Input/Output (500 VDC)  
>1’000 MOhm  
– On:  
2.5 ... 50 VDC or open circuit  
– Off:  
– Off idle current:  
0 ... +1.0 VDC or short circuit pin 6 and pin 2  
10 mA max.  
Switching frequency (fixed)  
Altitude during operation  
Safety standards  
400 kHz typ. (pulse width modulation PWM)  
5‘000 m max. (16‘400 ft) approved  
UL/cUL 60950-1, IEC/EN 60950-1  
Safety approvals  
– UL/cUL  
www.ul.com -> File no. e188913  
(entry pending)  
– CB test certificate according IEC 60950-1  
– CSA certificate for UL/cUL 60950-1  
www.tracopower.com/products/thl10wi-cb.pdf  
www.tracopower.com/products/thl10wi-csa.pdf  
Environmental compliance – Reach  
www.tracopower.com/products/thl10wi-reach.pdf  
RoHS directive 2002/95/EC  
– RoHS  
Physical Specifications  
Casing material  
Baseplate  
metal  
non conductive FR4  
epoxy (UL 94V-0 rated)  
15 g (0.53oz)  
Potting material  
Weight  
Soldering temperature  
max. +260°C / 10sec.  
Application note : www.tracopower.com/products/thl10wi-application.pdf  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
http://www.tracopower.com  
Page 3 of 4