欢迎访问ic37.com |
会员登录 免费注册
发布采购

PSP-500-15 参数 Datasheet PDF下载

PSP-500-15图片预览
型号: PSP-500-15
PDF下载: 下载PDF文件 查看货源
内容描述: 500W带PFC和并联功能 [500W with PFC and Parallel Function]
分类和应用: 功率因数校正
文件页数/大小: 5 页 / 213 K
品牌: TOTAL-POWER [ TOTAL POWER INTERNATIONAL ]
 浏览型号PSP-500-15的Datasheet PDF文件第2页浏览型号PSP-500-15的Datasheet PDF文件第3页浏览型号PSP-500-15的Datasheet PDF文件第4页浏览型号PSP-500-15的Datasheet PDF文件第5页  
TOTAL POWER INT'L  
500W with PFC and Parallel Function  
PSP-500 series  
Features :  
Universal AC input / Full range  
Built-in active PFC function, PF>0.95  
Protections:Short circuit/Over load/Over voltage/Over temperature  
Foced air cooling by built-in DC fan  
Current sharing up to 2000W(3+1)  
With power good and fail signal output  
Built-in remote ON-OFF control  
Built-in remote sense function  
3 years warranty  
SPECIFICATION  
MODEL  
PSP-500-5  
PSP-500-12  
PSP-500-13.5  
PSP-500-15  
PSP-500-24  
PSP-500-27  
PSP-500-48  
DC VOLTAGE  
5V  
12V  
13.5V  
15V  
24V  
27V  
48V  
RATED CURRENT  
CURRENT RANGE  
RATED POWER  
80A  
41.5A  
37A  
33A  
20.8A  
18.5A  
10.5A  
0 ~ 80A  
400W  
0 ~ 41.5A  
498W  
0 ~ 37A  
499.5W  
150mVp-p  
12 ~ 15V  
1.0%  
0 ~ 33A  
495W  
0 ~ 20.8A  
499.2W  
150mVp-p  
20 ~ 26.4V  
1.0%  
0 ~ 18.5A  
499.5W  
150mVp-p  
24 ~ 30V  
1.0%  
0 ~ 10.5A  
504W  
RIPPLE & NOISE (max.) Note.2 100mVp-p  
VOLTAGE ADJ. RANGE  
VOLTAGE TOLERANCE Note.3 2.0%  
150mVp-p  
10 ~ 13.2V  
1.0%  
150mVp-p  
13.5 ~ 18V  
1.0%  
200mVp-p  
41 ~ 56V  
1.0%  
OUTPUT  
4.75 ~ 5.5V  
LINE REGULATION  
LOAD REGULATION  
SETUP, RISE TIME  
HOLD TIME (Typ.)  
0.5%  
2.0%  
0.3%  
0.3%  
0.3%  
0.2%  
0.2%  
0.2%  
0.5%  
0.5%  
0.5%  
0.5%  
0.5%  
0.5%  
1500ms, 50ms at full load  
24ms at full load  
VOLTAGE RANGE  
Note.6 90 ~ 264VAC  
127 ~ 370VDC  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
EFFICIENCY (Typ.)  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
47 ~ 63Hz  
0.95/230VAC  
76%  
0.98/100VAC at full load  
INPUT  
82%  
82%  
82%  
84%  
84%  
86%  
7A/115AVC  
20A/115VAC  
<1mA / 240VAC  
3.5A/230VAC  
40A/230VAC  
LEAKAGE CURRENT  
110 ~ 125% rated output power  
Protection type : Constant current limiting, recovers automatically after fault condition is removed  
5.75 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 18.2V 18 ~ 21V 27.6 ~ 32.4V 31 ~ 36.5V  
Protection type : Shut down o/p voltage, re-power on to recover  
OVER LOAD  
57.6 ~ 67.2V  
PROTECTION OVER VOLTAGE  
RTH2 95 Detect on heatsink of Q1,Q7 power transistor & L3 output choke  
OVER TEMPERATURE  
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down  
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off  
-10 ~ +60 (Refer to output load derating curve)  
20 ~ 90% RH with 30CFM forced air non-condensing  
sink current <4 ~ 10mA  
FUNCTION REMOTE CONTROL  
WORKING TEMP.  
WORKING HUMIDITY  
-20 ~ +85 , 10 ~ 95% RH  
0.03%/ (0 ~ 50  
STORAGE TEMP., HUMIDITY  
ENVIRONMENT  
TEMP. COEFFICIENT  
VIBRATION  
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes  
UL60950-1, TUV EN60950-1 Approved  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
ISOLATION RESISTANCE  
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC  
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC  
SAFETY &  
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B  
EMC  
(Note 4)  
HARMONIC CURRENT  
EMS IMMUNITY  
MTBF  
Compliance to EN61000-3-2,-3  
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A  
130.1K hrs min. MIL-HDBK-217F (25  
278*129*63.5mm (L*W*H)  
)
OTHERS  
NOTE  
DIMENSION  
PACKING  
2.6Kg; 6pcs/15.7Kg/0.89CUFT  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives.  
5. In parallel connection, maybe only one unit operated, if the total output load less than 5% of rated load condition.  
6. Derating may be needed under low input voltages. Please check the derating curve for more details.