H HiTRON
04/22/2002
UNIVERSAL OR U.S. INPUT RANGE AC TO DC EXTERNAL
WALLMOUNT ADAPTERS SINGLE OUTPUT 12 WATTS
SWITCHING POWER SUPPLIES HES12 OR HES12B SERIES
FEATURES:
ꢀ LOW COST WALLMOUNT ADAPTER
ꢀ DIVERSE AC PLUGS AVAILABLE
ꢀ MEET DIVERSE SAFETY STANDARDS
ꢀ EMI MEET EN 55022 OR FCC CLASS B
ꢀ CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Input Voltage: HES12 typ. 90-264Vac, rating 100-240Vac.
HES12B typ. 90-132Vac, rating 120Vac.
Input Connector:
Output Current: See Ratings Chart.
Output Wattage: Typ. 12 Watts.
Output Connector: Optional.
Line Regulation: Typ. 0.1%.
Load Regulation: Typ. ±2-3%.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in. By Zener diode clamping.
Adjustability: Factory set.
HES12: WM1 (U.S.2-blade)/WM3 (Euro-stecker)/
DT8(IEC320-2P).
HES12B: WM1 (U.S.2-blade).
Input Frequency: 47-63Hz.
Inrush Current:
HES12: Typ. 28A @ 230Vac by adding thermister.
HES12B: Typ. 22.5A @ 115Vac.
Input Current: HES12 Typ. 0.15A @ 230Vac.
HES12B Typ. 0.24A @ 115Vac.
Overload Protection (OLP): Fully protected against output
overload or short circuit.
Typ. 120-150% max. load.
Consult the factory for special OLP setting
Dielectric Withstand: Meet IEC950.
EMI: Meet EN 55022 or FCC Class B.
Hold-up Time: Typ. 13.2mS@115Vac/42.0mS@230Vac.
GENERAL SPECIFICATION
Efficiency: Typ. 80.5%.
Operating Temperature: 0 to +40°C.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typ. 0.04% /°C.
Cooling: Free air convection.
Switching Frequency: Typ. 56-76K Hz.@ full load.
Circuit Topology: Free-running flyback circuit.
Transient Response: Output voltage returns typ. 1mS
following a 25% load change.
Construction: Impact resistant thermo-plastic
enclosure case.
Safety Standard: UL1950/EN60950.Class II.
Power Density: 2.3 Watts. / Cubic Inch.
Wallmount or Desktop format.
Notes: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 230Vac or 120Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m) cord AWG#18 wires.