TOSGAGE Series
X-ray Thickness Gage
General
The X-ray thickness gage is used to measure the
thickness of a strip continuously without
contacting that strip. This gage uses the fact that
the amount of radiation that passes through the
strip varies with the thickness of that strip.
The TOSGAGE-7525 is a high quality thickness
gage for cold rolling achieving outstanding safety,
operability, accuracy and cost-performance
developed over many years. It has the following
features.
•
Noise immunity is improved by digitizing the
signals between the measuring head and the
equipment cabinet.
TOSGAGE
-7525
•
The operation-PC uses Windows® NT, and is a
user-friendly PC.
•
A newly-developed X-ray generator is used,
providing extremely accurate measurement
results with a quick response time. The
TOSGAGE-7525 focuses X-ray beams finely in
the strip width direction to improve thickness
resolution in the strip width direction, and
making it suited to measuring the shape of the
section of measured materials.
The TOSGAGE-7525 can also be used as a AGC
backup for when the fixed thickness gage
(TOSGAGE-7521/7522) has failed.
Configuration
⑤CVVS
3C 5.5S(AC200V)
③CVVS
2C 3.5S(AC200V) ①CV 3C 3.5S(AC200V,1φ)
⑳CVVS
8C
1.25S
35
NC-HIV 8S
⑥CVVS
3C 8S(AC100V)
④CVVS
2C 3.5S(AC100V)
⑪
Special cable (power)
* Measuring head
⑦CVVS
20C
1.25S(Signal)
⑫
Special cable (Signal)
⑬
Special cable (Signal)
(Customer's
⑧CVVS 10P 1.25S(Signal)
D-type
⑭
Special cable (Snet)
computer)
⑮
Special cable (motor power supply)
⑨CVVS 10P 1.25S(Signal) CVVS
4P
1.25S(Signal)
22
PG
M B
23
CVVS 20C
1.25S(Signal)
⑩5C-2V-CCY
⑰
CVVS 2C 2S (reverse limit)
29
CVVS
10P 1.25S AUI AUI
26
27
24
⑱
CVVS 2C 2S (forward
(PG
Signal) AUI
Transceiver
Bridge
⑲
CVVS 2C 2S (standby)
34
Transceiver
* Limit switch
30
CVVS 2C 2S (line center)
25
Transceiver
21
NC-HIV 8S AUI
NC-HIV 8S
10BASE5
Conditions
28
1. Apart from special cables
⑪
to
⑮,
all cables are
(Operation-PC)
the responsibility of the customer.
C-type
D-type
2. Length of cable between equipment cabinet and
Printer
33
NC-HIV
32
X-ray/shutter
* Driving control box
* Equipment cabinet
*〈AVR〉
warning lamp
Customer's
distribution panel
⑯
Special cable (PG signal)
automatic voltage regulator is 10m max.
8S D-type
3. Distance between automatic voltage regulator and
customer's distribution board is 10m max.
4. Length of cable between driving control box and
31
CV
3C 3.5S(AC100V,1φ)
customer's distribution board is 100m max.
②CV
3C 5.5S(AC200V,1φ)
5. LAN and terminators are the responsibility of the customer.
(Hub) bridging and LAN separation are the responsibility of the
customer.
6. The application of flame-resistant cable (judgment and liability) is the responsibility of the customer.
7. Components marked * are standard configuration components.
Figure 1
Configuration and Cable Connections
No. EJD-069
1