欢迎访问ic37.com |
会员登录 免费注册
发布采购

XC6802A42XPR-G 参数 Datasheet PDF下载

XC6802A42XPR-G图片预览
型号: XC6802A42XPR-G
PDF下载: 下载PDF文件 查看货源
内容描述: 1节锂离子电池线性充电器IC,具有恒定电流/恒定电压 [1 Cell Li-ion Battery Linear Charger IC with Constant-Current/Constant-Voltage]
分类和应用: 电池
文件页数/大小: 18 页 / 351 K
品牌: TOREX [ TOREX SEMICONDUCTOR ]
 浏览型号XC6802A42XPR-G的Datasheet PDF文件第2页浏览型号XC6802A42XPR-G的Datasheet PDF文件第3页浏览型号XC6802A42XPR-G的Datasheet PDF文件第4页浏览型号XC6802A42XPR-G的Datasheet PDF文件第5页浏览型号XC6802A42XPR-G的Datasheet PDF文件第7页浏览型号XC6802A42XPR-G的Datasheet PDF文件第8页浏览型号XC6802A42XPR-G的Datasheet PDF文件第9页浏览型号XC6802A42XPR-G的Datasheet PDF文件第10页  
XC6802
Series
■OPERATIONAL
EXPLANATION (Continued)
I
BAT
Charge
Current
I
BAT
/10
4.20V
4.05V
Battery
Voltage
2.9V
Trickle
CC
CV
Standby
Recharge
Recharge Battery Time
(2ms, Typ)
Battery Termination Detect Time
(1ms, Typ)
/CHG Pin
Status
Strong Pull Down
(10mA, Typ)
Weak Pull Down
(20uA, Typ)
Strong Pull Down
(10mA, Typ)
<Charge Condition Status>
The /CHG pin constantly monitors the charge states classified as below:
●Strong
pull-down: I
/CHG
=10mA (TYP.) in a charge cycle,
●Weak
pull-down: I
/CHG
=20μA (TYP.) in a stand-by mode,
●High
impedance: in shutdown mode.
<Connection of Shorted BAT Pin>
Even if the BAT pin is shorted to the V
SS
, a trickle charge mode starts to operate for protecting the IC from destruction caused
by over current.
<Under-voltage Lockout (UVLO)>
The UVLO circuit keeps the charger in shut-down mode until the input voltage, V
IN
, rises more than the UVLO voltage.
Moreover, in order to protect the battery charger, the UVLO circuit keeps the charger in shut-down mode when a voltage
between the input pin voltage and BAT pin voltage falls to less than 30mV. The charge will not restart until the voltage
between the input pin voltage and BAT pin voltage rises more than 100mV. During the shut-down mode, the driver transistor
turns off but a failure detection circuit operates, and supply current is reduced to 10μA.
<Soft-Start Function>
To protect against inrush current from the input to the battery, soft-start time is set in the circuit optimally (100μs, TYP.).
<Manual Shut-Down>
During the charge cycle, the IC can be shifted to the shut-down mode by floating the I
SEN
pin. For this, a drain current to the
battery is reduced to less than 2μA and a shut-down current of the IC is reduced to less than 10μA. A new charge cycle
starts when reconnecting the current sense resistor.
<Opened BAT Pin>
When the BAT pin is left open, the IC needs to be shut-down once after monitoring the CHG pin by a microprocessor etc and
keeping the I
SEN
pin in H level.
<Backflow Prevention Between the BAT Pin and the VIN Pin>
A backflow prevention circuit protects against current flowing from the BAT pin to the V
IN
pin even the BAT pin voltage is higher
than the V
IN
pin voltage.
6/18