XBS053V13R-G
■TYPICAL PERFORMANCE CHARACTERISTICS
(1) Forward Current vs. Forward Voltage
(2) Reverse Current vs. Reverse Voltage
100
10
1
Ta=125℃
75℃
Ta=125℃
-25℃
0.1
0.01
1
0.1
75℃
25℃
25℃
0.01
0.001
0.001
0
10
20
30
0
0.2
0.4
0.6
150
30
Forward Voltage: VF (V)
Forward VoltageꢀVF (V)
Reverse Voltage: VR (V)
Reverse VoltageꢀVR (V)
(3) Forward Voltage vs. Operating Temperature
(4) Reverse Current vs. Operating Temperature
0.6
100
VR=20V
10V
5V
10
1
IF=0.5A
0.4
0.2
0.0
0.1
0.1A
0.01A
0.01
0.001
-50
0
50
100
0
50
100
150
Operating Temperature: Ta (℃)
Operating Temperature: Ta (℃)
Operating TemperatureꢀTa (℃)
Operating TemperatureꢀTa (℃)
(5) Inter-Terminal Capacity vs. Reverse Voltage
(6) Average Forward Current vs. Operating Temperature
1.0
100
0.8
0.5
0.3
0.0
75
50
25
0
Ta=25℃
0
10
20
0
50
100
150
Reverse Voltage: VR (V)
Operating Temperature: Ta (℃)
Operating TemperatureꢀTa (℃)
Reverse VoltageꢀVR (V)
2/3