TK115xx
TEST CIRCUIT 1
V
V
O
IN
S
S
S
S
1
2
3
4
8
7
6
5
V
ON/OFF
IN
BASE
GND
V
OUT
A
+
+
0.1mF
10mF
I
V
OUT
NC
V
ADJ
V
+
_
IN
ON/OFF
S
S
S
S
S
KT115xx • TC01
TK11530 ELECTRICAL CHARACTERISTICS
SYMBOL
PARAMETER
Supply Current 1
Supply Current 2
TEST CONDITIONS
MIN
TYP
500
1.4
MAX
900
2.5
UNITS
µA
I
V
V
= 4.0 V, | = 0 mA
CC1
IN
O
I
= 2.5 V, | = 0 mA
mA
µA
CC2
IN
O
I
Standby Supply Current V = 14 V, Output Off
0.2
2.0
CCS
IN
V
Output Voltage
Voltage Dropout
Output Current
V
= 4.0 V, | = 30 mA
2.9
3.0
3.1
V
O
IN
O
V
| = 60 mA
0.13
130
0.35
V
DROP
O
I
V = 2.7 V
100
mA
mA
O
O
I
Recommended
Output Current
100
30
OR
LinReg
Line Regulation
Load Regulation
V
= 4V→9 V
5.0
mV
IN
I = 0 to 30 mA, V = 4.0 V (Note 1)
18
36
55
50
80
mV
mV
dB
LoaReg
O
IN
I = 0 to 60 mA, V = 4.0 V (Note 1)
O
IN
RR
Ripple Regulation
100 mVrms, f = 400 Hz,
V
= 4.5 V, I = 10 mA
IN
O
∆V /∆T
V Temperature
V
= 4.5 V, I = 10 mA,
±0.3
mV/°C
O
A
O
IN
O
Coefficient
-20 °C ≤ T ≤ 75 °C
A
V
I
Output Noise Voltage
Base Terminal Current
10 Hz ≤ f ≤ 100 kHz, I = 10 mA
180
14
µVrms
NO
O
V
= 4.0 V
6
35
40
mA
B
IN
Active High Control Terminal
HC Terminal Current
I
Output On, Connect LC & GND
2
µA
V
HC
V
HC Terminal Voltage 1 Output On, Connect LC & GND
HC Terminal Voltage 2 Output Off, Connect LC & GND
2.4
0
V
HC1
HC2
IN
V
0.6
V
Active Low Control Terminal
I
LC Terminal Current
LC Terminal Voltage 1
LC Terminal Voltage 2
Output On, Connect HC & GND
Output On, Connect HC & GND
Output Off, Connect HC & GND
35
120
µA
V
LC
V
0
V -2.5
LC1
LC2
IN
V
V -0.2
V
V
IN
IN
Note 1: This is a pulse measurement where TJ is constant. The output change due to temperature is not included.
Page 2
February, 1995 TOKO, Inc.
10-15-94