TK112xxB
ABSOLUTE MAXIMUM RATINGS TK1121xBC (VOUT ≤ 1.9 V)
Supply Voltage ......................................................... 16 V
Power Dissipation SOT-23L (Note1) .................. 600 mW
Power Dissipation SOT-89 (Note1) .................... 900 mW
Reverse Bias.............................................................. 7 V
Storage Temperature Range ................... -55 to +150 °C
Operating Temperature Range ...................-30 to +80 °C
Operating Voltage Range............................ 1.8 to 14.5 V
Junction Temperature ........................................... 150 °C
TK1121xBC ELECTRICAL CHARACTERISTICS (VOUT ≤ 1.9 V)
Test conditions: T = 25 °C, unless otherwise specified.
A
SYMBOL
IQ
ISTBY
VOUT
PARAMETER
Quiescent Current
Standby Current
Output Voltage
TEST CONDITIONS
IOUT = 0 mA, Excluding ICONT
VIN = 8 V, Output OFF
IOUT = 30 mA
MIN
TYP
MAX
250
0.1
UNITS
µA
170
µA
See Table 2
V
Line Reg Line Regulation
(Note 2)
3.0
6
20
30
mV
mV
mV
mA
mA
I
I
OUT = 1 to 60 mA, (Note 2)
OUT = 1 to 100 mA, (Note 2)
2.4 V ≤ VIN ≤ 2.6 V, (Note 2)
Load Reg Load Regulation
18
60
130
150
IOUT
Continuous Output Current
VIN ≥ 2.6 V, (Note 2)
5 ms pulse, VIN ≥ 2.6 V,
12.5 % duty cycle
IOUT(PULSE)
Pulse Output Current
Ripple Rejection
180
mA
dB
f = 400 Hz, CL = 10 µF, CN = 0.1 µF,
VIN = VOUT + 1.5 V, IOUT = 30 mA,
VRIPPLE = 100 mVrms, (Note 3)
RR
VNO
55
30
10 Hz ≤ f ≤ 80 kHz, CL = 10 µF,
CN = 0.1 µF, VCN = VOUT + 1.5 V,
Output Noise Voltage
µVrms
I
OUT = 60 mA, (Notes 3,4)
Noise Bypass Terminal
Voltage
Vref
1.25
40
V
∆VOUT /∆T
Temperature Coefficient
IOUT = 10 mA
ppm/° C
CONTROL TERMINAL SPECIFICATIONS
ICONT
Control Current
VCONT = 1.8 V, Output ON
Output ON
12
35
µA
V
VCONT(ON)
Control Voltage ON
1.8
VCONT(OFF) Control Voltage OFF
Output OFF
0.6
V
Note 1: When mounted as recommended. Derate at 4.8 mw/°C for SOT-23L and 6.4 mw/°C for SOT-89 packages for operation above 25 °C.
Note 2: Refer to “Definition of Terms.”
Note 3: Ripple rejection and noise voltage are affected by the value and characteristics of the capacitor used.
Note 4: Output noise voltage can be reduced by connecting a capacitor to a noise pass terminal.
Gen Note: Parameters with min. or max. values are 100% tested at TA = 25 °C.
October 1999 TOKO, Inc.
Page 3