 浏览型号TRMA160808-YTRYH241的Datasheet PDF文件第2页浏览型号TRMA160808-YTRYH241的Datasheet PDF文件第3页浏览型号TRMA160808-YTRYH241的Datasheet PDF文件第4页浏览型号TRMA160808-YTRYH241的Datasheet PDF文件第5页浏览型号TRMA160808-YTRYH241的Datasheet PDF文件第6页浏览型号TRMA160808-YTRYH241的Datasheet PDF文件第7页浏览型号TRMA160808-YTRYH241的Datasheet PDF文件第8页浏览型号TRMA160808-YTRYH241的Datasheet PDF文件第10页  
TRMA High Current Inductors  
TOKEN  
Environmental Characteristics  
Item  
Specification  
Test Methods  
Flexure Strength The forces applied on  
the right conditions must  
Test device shall be soldered on the substrate Substrate  
Dimension:100×40×1.6mm  
Deflection: 2.0mm  
20  
not damage the terminal  
1.6  
electrode and the ferrite  
Keeping Time: 30sec  
For 0402, substrate dimension  
is 100×40×0.8mm  
2
45  
45  
Vibration  
Test device shall be soldered on the substrate  
Oscillation Frequency : 10 to 55 to 10Hz for 1min Amplitude :  
1.5mm  
Time : 2hrs for each axis (X,Y&Z), total 6hrs  
Resistance to  
Soldering  
Heat  
Appearance: No damage  
More than 75% of the  
terminal electrode should be Immersion Time: 10 ± 1sec  
covered with solder.  
Pre-heating: 150°C, 1min  
Solder Temperature: 260 ± 5°C  
Impedance: within± 30%  
of initial value  
Solderability  
The electrodes shall be  
at least 90% covered  
with new solder coating  
Pre-heating: 150°C, 1min  
Solder Temperature: 245 ± 5°C  
Immersion Time: 4 ± 1sec  
Terminal  
Strength  
Test  
0402 series : ≥0.2kg  
0603 series : ≥0.5kg  
0805 series : ≥1.0kg  
other series : ≥ 2.0kg  
Test device  
shall be soldered  
on the substrate  
W
Temperature  
Cycle  
Appearance: No damage  
Impedance: within ± 30%  
of initial value  
One cycle:  
One cycle/step1: -55 ± 3°C for 30mi  
step2: 25 ± 2°C for 3.0min  
step3:125 ± 3°C for 30min  
step4:25 ± 2°C for 3.0min  
Total: 100cycles  
Measured after exposure in the room condition for 24hrs  
Humidity  
Temperature: 40 ± 2°C  
Resistance  
Relative Humidity: 90 ~ 95% time: 1000hrs  
Measured after exposure in the room condition for 24hrs  
High  
Temperature: 125 ± 3°C  
Temperature  
Resistance  
Relative Humidity : 0%  
Applied Current: Rated Current time: 1000hrs  
Measured after exposure in the room condition for 24hrs  
Low  
Temperature: -55 ± 3°C  
Temperature  
Resistance  
TR elative Humidity : 0% time: 1000hrs  
Measured after exposure in the room condition for 24hrs  