2.11.40 Output Formatter 4 Register
Subaddress
Default
36h
FFh
7
6
5
4
3
2
1
0
VS/VBLK [1:0]
HS/CS [1:0]
C_1 [1:0]
C_0 [1:0]
VS/VBLK [1:0]: VS pin function select
00 = VS is logic 0 output.
01 = VS is logic 1 output.
10 = VS/VBLK is vertical sync or vertical blank output corresponding to bit 1 (VS/VBLK) in the sync control
register at subaddress 32h (see Section 2.11.36).
11 = VS is logic input (default).
HS/CS [1:0]: HS pin function select
00 = HS is logic 0 output.
01 = HS is logic 1 output.
10 = HS/CS is horizontal sync or composite sync output corresponding to bit 0 (HS/CS) in the sync control
register at subaddress 32h (see Section 2.11.36).
11 = HS is logic input (default).
C_1 [1:0]: C_1 pin function select
00 = C_1 is logic 0 output.
01 = C_1 is logic 1 output.
10 = Reserved
11 = C_1 is logic input (default).
C_0 [1:0]: C_0 pin function select
00 = C_0 is logic 0 output.
01 = C_0 is logic 1 output.
10 = Reserved
11 = C_0 is logic input (default).
C_x functions are only available at 10-bit output mode.
2−42