TS5A3157  
10-SPDT ANALOG SWITCH  
www.ti.com  
SCDS199JUNE 2005  
PARAMETER DESCRIPTION  
SYMBOL  
DESCRIPTION  
VCOM  
VNC  
Voltage at COM  
Voltage at NC  
Voltage at NO  
VNO  
ron  
Resistance between COM and NC or COM and NO ports when the channel is ON  
Difference of ron between channels in a specific device  
ron  
ron(flat)  
INC(OFF)  
INO(OFF)  
Difference between the maximum and minimum value of ron in a channel over the specified range of conditions  
Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the OFF state  
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the OFF state  
Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the ON state and the output  
(COM) open  
INC(ON)  
INO(ON)  
Leakage current measured at the NO port, with the corresponding channel (NO to COM) in the ON state and the output  
(COM) open  
Leakage current measured at the COM port, with the corresponding channel (COM to NO or COM to NC) in the ON state  
and the output (NC or NO) open  
ICOM(ON)  
VIH  
VIL  
Minimum input voltage for logic high for the control input (IN)  
Maximum input voltage for logic low for the control input (IN)  
Voltage at the control input (IN)  
VI  
IIH, IIL  
Leakage current measured at the control input (IN)  
Turn-on time for the switch. This parameter is measured under the specified range of conditions and by the propagation  
delay between the digital control (IN) signal and analog output (COM or NO) signal when the switch is turning ON.  
tON  
tOFF  
tBBM  
Turn-off time for the switch. This parameter is measured under the specified range of conditions and by the propagation  
delay between the digital control (IN) signal and analog output (COM or NO) signal when the switch is turning OFF.  
Break-before-make time. This parameter is measured under the specified range of conditions and by the propagation  
delay between the output of two adjacent analog channels (NC and NO) when the control signal changes state.  
Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NO or COM)  
output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the control  
input.Charge injection, QC = CL×∆ VCOM, CL is the load capacitance and VCOM is the change in analog output voltage.  
QC  
CNC(OFF)  
CNO(OFF)  
CNC(ON)  
CNO(ON)  
CCOM(ON)  
CI  
Capacitance at the NC port when the corresponding channel (NC to COM) is OFF  
Capacitance at the NO port when the corresponding channel (NO to COM) is OFF  
Capacitance at the NC port when the corresponding channel (NC to COM) is ON  
Capacitance at the NO port when the corresponding channel (NO to COM) is ON  
Capacitance at the COM port when the corresponding channel (COM to NC or COM to NO) is ON  
Capacitance of control input (IN)  
OFF isolation of the switch is a measurement of OFF-state switch impedance. This is measured in dB in a specific  
frequency, with the corresponding channel (NC to COM or NO to COM) in the OFF state.  
OISO  
BW  
THD  
I+  
Bandwidth of the switch. This is the frequency in which the gain of an ON channel is –3 dB below the DC gain.  
Total harmonic distortion is defined as the ratio of the root mean square (RMS) value of the second, third, and higher  
harmonics to the magnitude of fundamental harmonic.  
Static power-supply current with the control (IN) pin at V+ or GND  