欢迎访问ic37.com |
会员登录 免费注册
发布采购

TPS929160QDCPRQ1 参数 Datasheet PDF下载

TPS929160QDCPRQ1图片预览
型号: TPS929160QDCPRQ1
PDF下载: 下载PDF文件 查看货源
内容描述: [汽车级 16 通道 40V 高侧 LED 和 OLED 驱动器 | DCP | 38 | -40 to 125]
分类和应用: 驱动驱动器
文件页数/大小: 127 页 / 8604 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第39页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第40页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第41页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第42页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第44页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第45页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第46页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第47页  
TPS929160-Q1  
ZHCSNG0 – APRIL 2023  
www.ti.com.cn  
7.4 Device Functional Modes  
POR  
POR State  
(POR)  
EN = Logic High  
VBAT Good and  
LDO Good  
Initialization State  
(INIT)  
Configurable Init Delay  
INITTIMER  
0h: 0ms 8h: 200us  
1h: 50ms 9h: 100us  
2h: 20ms Ah: 50us  
3h: 10ms Bh: 50us  
4h: 5ms  
5h: 2ms  
6h: 1ms  
Ch: 50us  
Dh: 50us  
Eh: 50us  
WDTimer overflows or  
FORCEFS = 1  
7h: 500us Fh: 50us  
Normal State  
(NORMAL)  
Fail-Safe State  
(FAILSAFE)  
Clear Fail-safe  
CLRFS = 1  
Channel Directly  
Controlled by FS0 or FS1  
pins  
EEPROM Program Sequence:  
Write serial code to EEPGATE  
EEPMODE = 1  
EEPMODE = 0  
WDTimer  
WDTIMER  
0h: Disable 8h: 50ms  
Program State  
(PROG)  
1h: 200us  
2h: 500us  
3h: 1ms  
9h: 100ms  
Ah: 200ms  
Bh: 500ms  
4h: 2ms  
5h: 5ms  
6h: 10ms  
7h: 20ms  
Ch: Direct to FS  
Dh: Direct to FS  
Eh: Direct to FS  
Fh: Direct to FS  
Functional states  
7-11. Device Functional Mode Statemachine  
7.4.1 POR State  
Upon power up, the TPS929160-Q1 enters POWER_ON_RESET (POR) state. In this state, registers are  
cleared to default value, outputs are disabled, and the device cannot be accessed through the FlexWire  
interface.  
After both the VBAT input and the LDO output are above their UVLO threshold, the device switches to  
INITIALIZATION state (INIT). If any of the supply fails below UVLO threshold or EN pin is pulled low in other  
states, the device immediately switches to POR state.  
7.4.2 INITIALIZATION state  
The INITIALIZATION state is designed to allow master controller to have enough time to power up before the  
device automatically gets into FAIL-SAFE states. INIT mode has a configurable delay programmed by 4-bit  
register INITTIMER. After the delay counter is reached, the device changes to NORMAL state. In INIT state,  
the communication between master controller and the TPS929160-Q1 is enabled through FlexWire interface.  
In INITIALIZATION state, device automatically load register map default values, which can be programmed  
in corresponding EEPROM. The master controller sets CLRPOR to 1 in INITIALIZATION state, the device  
immediately switches to NORMAL state. Only write CLRPOR to TPS929160-Q1 in INITIALIZATION state.  
7.4.3 NORMAL state  
After the TPS929160-Q1 is in NORMAL state, the device operates under master control for LED animation  
and diagnostics using a FlexWire interface. The TPS929160-Q1 integrates a watchdog timer to monitor the  
Copyright © 2023 Texas Instruments Incorporated  
Submit Document Feedback  
43  
Product Folder Links: TPS929160-Q1  
English Data Sheet: SLVSG60  
 
 
 复制成功!