 浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第36页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第37页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第38页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第39页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第41页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第42页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第43页浏览型号TPS929160QDCPRQ1的Datasheet PDF文件第44页  
TPS929160-Q1  
ZHCSNG0 – APRIL 2023  
www.ti.com.cn  
7-8. Diagnostics Table in FAIL-SAFE state  
FAULT TYPE  
DETECTION CRITERIA  
CONDITIONS  
FAULT ACTIONS  
FAULT OUTPUT  
ERR PIN  
RECOVERY  
V(VBAT) < V(POR_falling)  
or  
V(LDO) < V(LDO_POR_falling)  
Device switch to INIT state when  
all voltage rails are good.  
Clear fault flag with CLRPOR.  
Device switch to FLAG_POR  
POR state FLAG_ERR  
Constant pulled  
down  
VBAT UVLO  
Automatically recovery upon fault  
removal.  
Clear fault flag with CLRFAULT.  
Low-supply  
warning  
Disable fault type FLAG_LOWSUP  
V(SUPPLY) < V(LOWSUPTH)  
No action  
*
FLAG_ERR (maskable)  
Automatically recovery and  
release ERR pin upon fault  
FLAG_ERR (maskable) down (maskable) removal.  
Clear fault flag with CLRFAULT.  
Supply  
undervoltage  
Turn off all  
outputs  
FLAG_SUPUV  
Constant pulled  
V(SUPPLY) < V(SUPUV_th_falling)  
Automatically recover and  
release ERR pin upon fault  
FLAG_ERR (maskable) down (maskable) removal.  
Clear fault flags with CLRFAULT.  
V(REF) < V(REF_SHORT_th)  
or  
I(REF) < I(REF_OPEN_th)  
Turn off all  
outputs  
FLAG_REF  
Constant pulled  
Reference fault  
Pre-thermal  
warning  
FLAG_PRETSD  
FLAG_ERR(maskable)  
T(J) > T(PRETSD)  
No action  
No action  
Clear fault flag with CLRFAULT  
Automatically recover and  
release ERR pin upon fault  
FLAG_ERR (maskable) down (maskable) removal.  
Clear fault flags with CLRFAULT.  
Overtemperature  
protection  
Turn off all  
outputs  
FLAG_TSD  
Constant pulled  
T(J) > T(TSD1)  
Device switch to INIT state when  
all voltage rails are good.  
Clear fault flag with CLRPOR.  
Overtemperature  
shutdown  
FLAG_POR  
FLAG_ERR  
Constant pulled  
down  
T(J) > T(TSD2)  
Turn off LDO  
PWM pulse width greater than  
t(BLANK) + t(OPEN_deg)  
ENOUTXn = 1  
Automatically recover and  
release ERR pin upon fault  
down (maskable) removal.  
V(SUPPLY) - V(OUTXn) < V(OPEN_th_rising)  
and  
Turn off the failed FLAG_OPENOUTXn  
outputs and retry FLAG_OUT (maskable)  
LED open-circuit  
fault *  
Constant pulled  
V(SUPPLY) > V(LOWSUPTH)  
every 10 ms  
FLAG_ERR (maskable)  
DIAGENOUTXn = 1  
Clear fault flags with CLRFAULT.  
PWM pulse width greater than  
t(BLANK) + t(SHORT_deg)  
ENOUTXn = 1  
Automatically recover and  
release ERR pin upon fault  
down (maskable) removal.  
Turn off the failed FLAG_SHORTOUTXn  
outputs and retry FLAG_OUT (maskable)  
LED short-circuit  
fault  
Constant pulled  
V(OUTXn) < V(SG_th_rising)  
every 10 ms  
FLAG_ERR (maskable)  
DIAGENOUTXn = 1  
Clear fault flags with CLRFAULT.  
PWM pulse width greater than  
t(BLANK)+ t(SLS_deg)  
ENOUTXn = 1  
DIAGENOUTXn = 1  
SLSEN = 1  
Automatically recover and  
release ERR pin upon fault  
removal.  
V(OUTXn) < V(SLSTHx)  
and  
V(SUPPLY) > V(LOWSUPTH)  
Turn off the failed FLAG_SLSOUTXn  
outputs and retry FLAG_OUT (Maskable)  
Auto single-LED  
short-circuit *  
Constant pulled  
down  
every 10 ms  
FLAG_ERR (Maskable)  
Clear fault flags with CLRFAULT.  
EEPROM CRC  
error  
Turn off all  
outputs  
FLAG_EEPCRC  
FLAG_ERR (maskable) down (maskable)  
Constant pulled  
CALC_EEPCRC is different EEPCRC  
Clear fault flag with CLRFAULT  
Copyright © 2023 Texas Instruments Incorporated  
English Data Sheet: SLVSG60  
40  
Submit Document Feedback  
Product Folder Links: TPS929160-Q1  
 
 复制成功!