TPS7415, TPS7418, TPS7425, TPS7430, TPS7433
FAST-TRANSIENT-RESPONSE USING SMALL OUTPUT CAPACITOR
200-mA LOW-DROPOUT VOLTAGE REGULATORS
SLVS212 – DECEMBER 1999
Terminal Functions
TERMINAL
NAME
I/O
DESCRIPTION
NO.
1
EN
I
Enable input
GND
IN
6
Regulator ground
Input voltage
4, 5
2, 3
7
I
NC
Not connected
Regulated output voltage
Sense
OUT
O
I
SENSE
8
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
‡
Input voltage range , V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 8 V
I
Voltage range at EN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to V + 0.3 V
I
Peak output current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally limited
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See dissipation rating tables
Operating virtual junction temperature range, T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 125°C
J
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
stg
†
‡
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
All voltage values are with respect to network terminal ground.
DISSIPATION RATING TABLE 1 – FREE-AIR TEMPERATURES
AIR FLOW
(CFM)
T
< 25°C
DERATING FACTOR
T
= 70°C
T = 85°C
A
A
A
PACKAGE
POWER RATING
ABOVE T = 25°C
POWER RATING POWER RATING
A
0
568 mW
5.68 mW/°C
9.04 mW/°C
312 mW
497 mW
227 mW
361 mW
D
250
904 mW
recommended operating conditions
MIN
MAX
UNIT
V
§
Input voltage, V
2.5
0
7
200
125
I
Output current, I (see Note 1)
mA
°C
O
Operating virtual junction temperature, T (see Note 1)
–40
J
§
To calculate the minimum input voltage for your maximum output current, use the following equation: V
I(min)
= V
+ V
.
DO(max load)
O(max)
NOTE 1: Continuous current and operating junction temperature are limited by internal protection circuitry, but it is not recommended that the
device operate under conditions beyond those specified in this table for extended periods of time.