APPLICATION INFORMATION  
POWER-SUPPLY CONSIDERATIONS  
TPS2042B  
2
Power Supply  
IN  
7
2.7 V to 5.5 V  
Load  
Load  
OUT1  
0.1 µF  
0.1 µF  
0.1 µF  
22 µF  
22 µF  
8
OC1  
EN1  
OC2  
3
5
6
OUT2  
4
EN2  
GND  
1
Figure 28. Typical Application (Example, TPS2042B)  
A 0.01-µF to 0.1-µF ceramic bypass capacitor between IN and GND, close to the device, is recommended.  
Placing a high-value electrolytic capacitor on the output pin(s) is recommended when the output load is heavy.  
This precaution reduces power-supply transients that may cause ringing on the input. Additionally, bypassing the  
output with a 0.01-µF to 0.1-µF ceramic capacitor improves the immunity of the device to short-circuit transients.  
OVERCURRENT  
A sense FET is employed to check for overcurrent conditions. Unlike current-sense resistors, sense FETs do not  
increase the series resistance of the current path. When an overcurrent condition is detected, the device  
maintains a constant output current and reduces the output voltage accordingly. Complete shutdown occurs only  
if the fault is present long enough to activate thermal limiting.  
Three possible overload conditions can occur. In the first condition, the output has been shorted before the  
device is enabled or before VI(IN) has been applied (see Figure 14 through Figure 17). The TPS204xB/TPS205xB  
senses the short and immediately switches into a constant-current output.  
In the second condition, a short or an overload occurs while the device is enabled. At the instant the overload  
occurs, high currents may flow for a short period of time before the current-limit circuit can react. After the  
current-limit circuit has tripped (reached the overcurrent trip threshold), the device switches into constant-current  
mode.  
In the third condition, the load has been gradually increased beyond the recommended operating current. The  
current is permitted to rise until the current-limit threshold is reached or until the thermal limit of the device is  
exceeded (see Figure 18 through Figure 21). The TPS204xB/TPS205xB is capable of delivering current up to the  
current-limit threshold without damaging the device. Once the threshold has been reached, the device switches  
into its constant-current mode.  
OC RESPONSE  
The OCx open-drain output is asserted (active low) when an overcurrent or overtemperature shutdown condition  
is encountered after a 10-ms deglitch timeout. The output remains asserted until the overcurrent or  
overtemperature condition is removed. Connecting a heavy capacitive load to an enabled device can cause a  
momentary overcurrent condition; however, no false reporting on OCx occurs due to the 10-ms deglitch circuit.  
The TPS204xB/TPS205xB is designed to eliminate false overcurrent reporting. The internal overcurrent deglitch  
eliminates the need for external components to remove unwanted pulses. OCx is not deglitched when the switch  
is turned off due to an overtemperature shutdown.  