TLV431, TLV431A, TLV431B
LOW VOLTAGE ADJUSTABLE PRECISION SHUNT REGULATOR
SLVS139R − JULY 1996 − REVISED SEPTEMBER 2005
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Cathode voltage, V
KA
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Continuous cathode current range, I
K
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −20 mA to 20 mA
Reference current range, I
ref
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.05 mA to 3 mA
Package thermal impedance,
θ
JA
(see Notes 2 and 3): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W
DBV package . . . . . . . . . . . . . . . . . . . . . . . . 206°C/W
DBZ package . . . . . . . . . . . . . . . . . . . . . . . . . 206°C/W
DCK package . . . . . . . . . . . . . . . . . . . . . . . . 252°C/W
LP package . . . . . . . . . . . . . . . . . . . . . . . . . . 140°C/W
PK package . . . . . . . . . . . . . . . . . . . . . . . . . . . 52°C/W
Operating virtual junction temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Voltage values are with respect to the anode terminal, unless otherwise noted.
2. Maximum power dissipation is a function of TJ(max),
θ
JA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) − TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
MIN
VKA
IK
TA
Cathode voltage
Cathode current
TLV431_C
Operating free-air temperature range
TLV431_I
TLV431_Q
VREF
0.1
0
−40
−40
MAX
6
15
70
85
125
°C
C
UNIT
V
mA
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
5