2 Specifications
2.1 Absolute Maximum Ratings Over Operating Free-Air Temperature Range (unless
†
otherwise noted)
Supply voltage range, AV
to AGND, DV
to DGND, BV
to DGND, HPV
to HPGND
DD
DD
DD
DD
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to + 3.63 V
Analog supply return to digital supply return, AGND to DGND . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to + 3 .63 V
Input voltage range, all input signals: Digital . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to DV
Analog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to AV
+ 0.3 V
+ 0.3 V
DD
DD
Case temperature for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240°C
Operating free-air temperature range, T Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −10°C to 70°C
A:
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
Storage temperature range, T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: DV
DD
may not exceed BV
DD
+ 0.3V; BV
DD
may not exceed AV
DD
+ 0.3V or HPV + 0.3.
DD
2.2 Recommended Operating Conditions
MIN NOM
MAX
3.6
UNIT
Analog supply voltage, AV , HPV
DD DD
(see Note 2)
2.7
2.7
3.3
3.3
1.5
1
V
V
V
Digital buffer supply voltage, BV
(see Note 2)
3.6
DD
(see Note 2)
Digital core supply voltage, DV
DD
1.42
3.6
Analog input voltage, full scale − 0dB (AV
= 3.3 V)
V
RMS
DD
Stereo-line output load resistance
10
0
kΩ
Headphone-amplifier output load resistance
CLKOUT digital output load capacitance
All other digital output load capacitance
Stereo-line output load capacitance
XTI master clock Input
Ω
pF
20
10
50
pF
pF
18.43
96
MHz
kHz
ADC or DAC conversion rate
Commercial
Industrial
−10
−40
70
Operating free-air temperature, T
°C
A
85
NOTE 2: Digital voltage values are with respect to DGND; analog voltage values are with respect to AGND.
2−1