3.3.2.2 Normal-Mode Sampling Rates
In normal mode, the following ADC and DAC sampling rates, depending on the MCLK frequency, are available:
MCLK = 12.288 MHz
SAMPLING RATE
SAMPLING-RATE CONTROL SETTINGS
FILTER TYPE
ADC
DAC
SR3
SR2
SR1
SR0
BOSR
(kHz)
(kHz)
96
48
32
8
96
48
32
8
2
1
1
1
1
1
0
0
0
0
0
0
1
0
1
0
0
0
1
0
1
1
0
1
1
0
0
1
1
0
0
0
0
0
0
0
48
8
8
48
MCLK = 11.2896 MHz
SAMPLING RATE
SAMPLING-RATE CONTROL SETTINGS
FILTER TYPE
ADC
DAC
SR3
SR2
SR1
SR0
BOSR
(kHz)
(kHz)
88.2
44.1
88.2
44.1
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
1
0
1
0
1
1
0
1
1
0
0
0
0
0
0
8.021
44.1
8.021
8.021
44.1
8.021
MCLK = 18.432 MHz
SAMPLING RATE
SAMPLING-RATE CONTROL SETTINGS
FILTER TYPE
ADC
DAC
SR3
SR2
SR1
SR0
BOSR
(kHz)
(kHz)
96
48
32
8
96
48
32
8
2
1
1
1
1
1
0
0
0
0
0
0
1
0
1
0
0
0
1
0
1
1
0
1
1
0
0
1
1
0
1
1
1
1
1
1
48
8
8
48
MCLK = 16.9344 MHz
SAMPLING RATE
SAMPLING-RATE CONTROL SETTINGS
FILTER TYPE
ADC
DAC
SR3
SR2
SR1
SR0
BOSR
(kHz)
(kHz)
88.2
44.1
88.2
44.1
2
1
1
1
1
1
1
1
1
1
1
0
0
0
0
1
0
1
0
1
1
0
1
1
0
1
1
1
1
1
8.021
44.1
8.021
8.021
44.1
8.021
3−10