TLC5620C, TLC5620I
QUADRUPLE 8-BIT DIGITAL-TO-ANALOG CONVERTERS
SLAS081E – NOVEMBER 1994 – REVISED NOVEMBER 2001
equivalent inputs and outputs
INPUT CIRCUIT
VDD
Input from
Decoded DAC
Register String
_
+
×
1
84 kΩ
ISINK
60
µA
Typical
GND
DAC
Voltage Output
OUTPUT CIRCUIT
VDD
Vref
Input
To DAC
Resistor
String
GND
Output
Range
×
2
Select
84 kΩ
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage (V
DD
– GND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Digital input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND – 0.3 V to V
DD
+ 0.3 V
Reference input voltage range, V
ID
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GND – 0.3 V to V
DD
+ 0.3 V
Operating free-air temperature range, T
A
: TLC5620C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TLC5620I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 50°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
MIN
Supply voltage, VDD
High-level input voltage, VIH
Low-level input voltage, VIL
Reference voltage, Vref [A|B|C|D]
Analog full-scale output voltage, RL = 10 kΩ
Load resistance, RL
Setup time, data input, tsu(DATA-CLK) (see Figures 1 and 2)
Valid time, data input valid after CLK↓, tv(DATA-CLK) (see Figures 1 and 2)
Setup time, CLK eleventh falling edge to LOAD, tsu(CLK-LOAD) (see Figure 1)
Setup time, LOAD↑ to CLK↓, tsu(LOAD-CLK) (see Figure 1)
Pulse duration, LOAD, tw(LOAD) (see Figure 1)
Pulse duration, LDAC, tw(LDAC) (see Figure 2)
Setup time, LOAD↑ to LDAC↓, tsu(LOAD-LDAC) (see Figure 2)
CLK frequency
Operating free-air temperature, TA
free air temperature
TLC5620C
TLC5620I
0
– 40
10
50
50
50
50
250
250
0
1
70
85
3.5
4.75
0.8 VDD
0.8
VDD – 1.5
NOM
MAX
5.25
UNIT
V
V
V
V
V
kΩ
ns
ns
ns
ns
ns
ns
ns
MHz
°C
°C
6
POST OFFICE BOX 655303
•