欢迎访问ic37.com |
会员登录 免费注册
发布采购

TLC555CDRG4 参数 Datasheet PDF下载

TLC555CDRG4图片预览
型号: TLC555CDRG4
PDF下载: 下载PDF文件 查看货源
内容描述: LinCMOSE定时器 [LinCMOSE TIMERS]
分类和应用:
文件页数/大小: 19 页 / 400 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号TLC555CDRG4的Datasheet PDF文件第1页浏览型号TLC555CDRG4的Datasheet PDF文件第2页浏览型号TLC555CDRG4的Datasheet PDF文件第3页浏览型号TLC555CDRG4的Datasheet PDF文件第4页浏览型号TLC555CDRG4的Datasheet PDF文件第6页浏览型号TLC555CDRG4的Datasheet PDF文件第7页浏览型号TLC555CDRG4的Datasheet PDF文件第8页浏览型号TLC555CDRG4的Datasheet PDF文件第9页  
ꢀꢁ ꢂꢃ ꢃꢃ  
ꢀꢉ ꢆ ꢊ ꢋ  
SLFS043F − SEPTEMBER 1983 − REVISED FEBRUARY 2005  
electrical characteristics at specified free-air temperature, V  
TLC555I  
= 2 V for TLC555C, V  
= 3 V for  
DD  
DD  
TLC555C  
TYP  
TLC555I  
TYP  
TEST  
PARAMETER  
Threshold voltage  
Threshold current  
Trigger voltage  
Trigger current  
Reset voltage  
UNIT  
T
A
CONDITIONS  
MIN  
0.95  
0.85  
MAX  
1.65  
1.75  
MIN  
1.6  
MAX  
2.4  
25°C  
Full range  
25°C  
1.33  
V
IT  
V
pA  
V
1.5  
2.5  
10  
75  
10  
150  
1
I
IT  
MAX  
25°C  
0.4  
0.3  
0.67  
0.95  
1.05  
0.71  
0.61  
1.29  
1.39  
V
I(TRIG)  
I(TRIG)  
Full range  
25°C  
10  
75  
10  
150  
1.1  
I
pA  
V
MAX  
25°C  
0.4  
0.3  
1.1  
1.5  
2
0.4  
0.3  
1.5  
1.8  
V
I(RESET)  
Full range  
25°C  
10  
75  
10  
I
Reset current  
pA  
I(RESET)  
MAX  
150  
Control voltage (open circuit) as  
a percentage of supply voltage  
MAX  
66.7%  
0.03  
66.7%  
0.03  
25°C  
Full range  
25°C  
0.2  
0.2  
Discharge switch on-stage  
voltage  
I
= 1 mA  
V
nA  
V
OL  
0.25  
0.375  
0.1  
0.5  
1.9  
0.1  
120  
Discharge switch off-stage  
current  
MAX  
25°C  
1.5  
1.5  
2.5  
2.5  
2.85  
V
V
High-level output voltage  
Low-level output voltage  
Supply current  
I
I
= 300 µA  
OH  
OH  
Full range  
25°C  
0.07  
0.3  
0.35  
250  
400  
0.07  
0.3  
0.4  
= 1 mA  
V
OL  
OL  
Full range  
25°C  
250  
500  
I
See Note 2  
µA  
DD  
Full range  
Full range is 0°C to 70°C for the TLC555C and −40°C to 85°C for the TLC555I. For conditions shown as MAX, use the appropriate value specified  
in the recommended operating conditions table.  
NOTE 2: These values apply for the expected operating configurations in which THRES is connected directly to DISCH or to TRIG.  
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265