ꢀ ꢁ ꢂ ꢃꢃ ꢃ
ꢄ
ꢁ
ꢅ
ꢂ
ꢆ
ꢇ
ꢈ
ꢀ ꢉ ꢆꢊ ꢋ
SLFS043F − SEPTEMBER 1983 − REVISED FEBRUARY 2005
electrical characteristics at specified free-air temperature, V
= 5 V
DD
TLC555C
TYP
TLC555I
TYP
TLC555Q, TLC555M
TEST
CONDITIONS
†
PARAMETER
Threshold voltage
Threshold current
Trigger voltage
Trigger current
Reset voltage
UNIT
V
T
A
MIN
2.8
MAX
3.8
MIN
2.8
MAX
3.8
MIN
2.8
TYP
MAX
3.8
3.3
3.3
3.3
25°C
Full range
25°C
V
I
IT
2.7
3.9
2.7
3.9
2.7
3.9
10
75
10
150
10
5000
1.66
pA
V
IT
MAX
1.36
1.26
1.66
1.96
2.06
1.36
1.26
1.66
1.96
2.06
1.36
1.26
1.96
2.06
25°C
V
I(TRIG)
Full range
10
75
10
150
1.1
10
5000
1.1
25°C
I
pA
V
I(TRIG)
MAX
0.4
0.3
1.1
1.5
1.8
0.4
0.3
1.5
1.8
0.4
0.3
1.5
1.8
25°C
V
I(RESET)
Full range
10
75
10
10
25°C
I
Reset current
pA
I(RESET)
MAX
150
5000
Control voltage (open
circuit) as a percent-
age of supply voltage
MAX
66.7%
0.14
66.7%
0.14
66.7%
0.14
0.5
0.6
0.5
0.6
0.5
0.6
25°C
Full range
25°C
Discharge switch
on-state voltage
I
= 10 mA
V
nA
V
OL
0.1
0.5
4.8
0.1
120
4.8
0.1
120
4.8
Discharge switch
off-state current
MAX
4.1
4.1
4.1
4.1
4.1
4.1
25°C
High-level output
voltage
V
V
I
I
I
I
= − 1 mA
= 8 mA
OH
OH
OL
OL
OL
Full range
0.21
0.13
0.08
170
0.4
0.5
0.21
0.13
0.08
170
0.4
0.5
0.21
0.13
0.08
170
0.4
0.6
25°C
Full range
25°C
0.3
0.3
0.3
Low-level output
voltage
= 5 mA
V
OL
Full range
0.4
0.4
0.45
0.3
0.3
0.3
25°C
= 3.2 mA
Full range
25°C
0.35
350
500
0.35
350
600
0.4
350
700
µA
I
Supply current
See Note 2
DD
Full range
†
Full range is 0°C to 70°C the for TLC555C, −40°C to 85°C for the TLC555I, −40°C to 125°C for the TLC555Q, and −55°C to 125°C for the
TLC555M. For conditions shown as MAX, use the appropriate value specified in the recommended operating conditions table.
NOTE 2: These values apply for the expected operating configurations in which THRES is connected directly to DISCH or TRIG.
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265