SLOS190G − FEBRUARY 1997 − REVISED MAY 2004
TLC227x, TLC227xA
Advanced LinCMOS RAIL TO RAIL
OPERATIONAL AMPLIFIERS
TLC2274C electrical characteristics at specified free-air temperature, V
DD
= 5 V (unless otherwise
noted)
PARAMETER
VIO
α
VIO
Input offset voltage
Temperature coefficient
of input offset voltage
Input offset voltage
long-term drift
(see Note 4)
IIO
IIB
Input offset current
Input bias current
VDD
±
=
±
2.5 V,
VO = 0 V,
VIC = 0 V,
RS = 50
Ω
TEST CONDITIONS
TA†
25°C
Full range
25°C
to 70°C
25°C
25°C
Full range
25°C
Full range
25°C
RS = 50
Ω,
IOH = − 20
µA
VOH
High-level output voltage
IOH = − 200
µA
IOH = − 1 mA
VIC = 2.5 V,
VOL
Low-level output voltage
VIC = 2.5 V,
VIC = 2.5 V,
Large-signal differential
voltage amplification
Differential input
resistance
Common-mode input
resistance
Common-mode input
capacitance
Closed-loop output
impedance
Common-mode rejection
ratio
Supply-voltage rejection
ratio (∆VDD /∆VIO)
Supply current
f = 10 kHz,
f = 1 MHz,
N package
AV = 10
VIC = 2.5 V,
VO = 1 V to 4 V
IOL = 50
µA
IOL = 500
µA
IOL = 5
mA
RL = 10 kه
RL = 1 mه
V
IO
≤
5 mV,
Full range
25°C
25°C
Full range
25°C
Full range
25°C
25°C
Full range
25°C
Full range
25°C
Full range
25°C
25°C
25°C
25°C
25°C
25°C
Full range
25°C
Full range
25°C
IDD
VO = 2.5 V,
No load
Full range
70
70
80
80
4.4
6
6
95
15
15
175
1012
1012
8
140
75
70
70
80
80
4.4
6
6
mA
95
35
0.9
4.85
4.85
4.25
4.25
0.01
0.09
0.15
0.15
1.5
1.5
15
15
175
1012
1012
8
140
75
Ω
Ω
pF
Ω
dB
dB
35
V/mV
0.9
4.65
0
to 4
0 to
3.5
4.99
4.93
4.85
4.85
4.25
4.25
0.01
0.09
0.15
0.15
1.5
1.5
V
4.65
−0.3
to 4.2
1
2
TLC2274C
MIN
TYP
300
MAX
2500
3000
2
TLC2274AC
MIN
TYP
300
MAX
950
1500
UNIT
µV
µV/°C
µV/mo
60
100
1
0
to 4
0 to
3.5
4.99
4.93
V
−0.3
to 4.2
60
100
0.002
0.5
60
100
60
100
0.002
0.5
pA
pA
VICR
Common-mode input
voltage
V
AVD
rid
ri
ci
zo
CMRR
kSVR
VIC = 0 V to 2.7 V,
VO = 2.5 V,
RS = 50
Ω
VDD = 4.4 V to 16 V,
VIC = VDD /2,
No load
† Full range is 0°C to 70°C.
‡ Referenced to 0 V
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
10
POST OFFICE BOX 655303
•