ꢀ ꢁꢂ ꢃ ꢄ ꢅ ꢀ ꢁꢂ ꢃ ꢄ ꢆꢅ ꢀ ꢁꢂ ꢃ ꢄ ꢇꢅ ꢀ ꢁꢂ ꢃ ꢈ ꢅ ꢀ ꢁꢂ ꢃ ꢈ ꢆ ꢅ ꢀꢁ ꢂꢃ ꢈꢇ  
ꢆꢉꢊ ꢋꢌ ꢀꢆꢇꢁ ꢍ ꢎꢏ ꢍꢐꢑꢌ ꢑꢒ ꢓ ꢌꢔꢋ ꢓꢀ ꢏꢍ ꢕ ꢋꢁ ꢆꢀꢒ ꢏꢌ  
SLVS543A – AUGUST 2004 − REVISED AUGUST 2004  
electrical characteristics over recommended operating conditions, T = 25°C (unless otherwise  
A
noted)  
TL431I, TL432I  
TEST  
CIRCUIT  
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN  
2440  
TYP  
MAX  
V
ref  
Reference voltage  
2
2
V
= V  
= V  
,
I = 10 mA  
KA  
2495  
2550  
mV  
KA  
ref  
SOT23-3 and TL432  
devices  
Deviation of reference voltage  
over full temperature range  
(see Figure 1)  
V
I
T
A
KA  
KA  
ref,  
= 10 mA,  
14  
34  
V
I(dev)  
mV  
= −40°C to 85°C  
All other devices  
5
−1.4  
−1  
50  
−2.7  
−2  
V  
V  
= 10 V − V  
ref  
Ratio of change in reference voltage  
to the change in cathode voltage  
KA  
DVref  
DVKA  
mV  
V
3
3
I
I
I
= 10 mA  
KA  
KA  
KA  
= 36 V − 10 V  
KA  
I
Reference current  
= 10 mA, R1 = 10 k, R2 = ∞  
2
4
µA  
ref  
Deviation of reference current  
over full temperature range  
(see Figure 1)  
= 10 mA, R1 = 10 k, R2 = ,  
= −40°C to 85°C  
I
3
0.8  
2.5  
µA  
I(dev)  
T
A
Minimum cathode current for  
regulation  
I
I
2
4
2
V
V
= V  
ref  
0.4  
0.1  
0.2  
1
1
mA  
µA  
min  
KA  
Off-state cathode current  
= 36 V,  
V
ref  
= 0  
off  
KA  
I
= 1 mA to 100 mA, V  
= V ,  
ref  
KA  
f 1 kHz  
KA  
|z  
|
Dynamic impedance (see Figure 1)  
0.5  
KA  
electrical characteristics over recommended operating conditions, T = 25°C (unless otherwise  
A
noted)  
TL431Q, TL432Q  
TEST  
CIRCUIT  
PARAMETER  
TEST CONDITIONS  
UNIT  
MIN  
TYP  
MAX  
V
Reference voltage  
2
V
V
T
A
= V  
= V  
,
I
= 10 mA  
2440  
2495  
2550  
mV  
ref  
KA  
ref  
KA  
Deviation of reference voltage  
over full temperature range  
(see Figure 1)  
I
= 10 mA,  
KA  
ref, KA  
V
I(dev)  
2
14  
34  
mV  
= −40°C to 125°C  
V  
= 10 V − V  
ref  
−1.4  
−1  
2
−2.7  
−2  
4
Ratio of change in reference voltage  
to the change in cathode voltage  
KA  
DVref  
DVKA  
mV  
V
3
3
I
I
I
= 10 mA  
KA  
KA  
KA  
V  
= 36 V − 10 V  
KA  
I
Reference current  
= 10 mA, R1 = 10 k, R2 = ∞  
µA  
ref  
Deviation of reference current  
over full temperature range  
(see Figure 1)  
= 10 mA, R1 = 10 k, R2 = ,  
= −40°C to 125°C  
I
3
0.8  
2.5  
µA  
I(dev)  
T
A
Minimum cathode current for  
regulation  
I
I
2
4
2
V
V
= V  
ref  
0.4  
0.1  
0.2  
1
1
mA  
µA  
min  
KA  
Off-state cathode current  
= 36 V,  
V
= 0  
off  
KA  
ref  
I
= 1 mA to 100 mA, V  
= V ,  
ref  
KA  
f 1 kHz  
KA  
|z  
|
Dynamic impedance (see Figure 1)  
0.5  
KA  
11  
POST OFFICE BOX 655303 DALLAS, TEXAS 75265