TL431, TL431A, TL431B
TL432, TL432A, TL432B
ADJUSTABLE PRECISION SHUNT REGULATORS
SLVS543J − AUGUST 2004 − REVISED DECEMBER 2005
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
‡
Cathode voltage, V
KA
(see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 V
Continuous cathode current range, I
KA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −100 mA to 150 mA
Reference input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −50
µA
to 10 mA
Operating virtual junction temperature, T
J
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
‡ Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: Voltage values are with respect to the ANODE terminal, unless otherwise noted.
package thermal data (see Note 2)
PACKAGE
PDIP (P)
SC-70 (DCK)
SOIC (D)
SOP (PS)
SOT-89 (PK)
SOT-23-5 (DBV)
SOT-23-3 (DBZ)
TO-92 (LP)
TSSOP (PW)
BOARD
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-7
θ
JC
57°C/W
259°C/W
39°C/W
46°C/W
9°C/W
131°C/W
76°C/W
55°C/W
65°C/W
θ
JA
85°C/W
87°C/W
97°C/W
95°C/W
52°C/W
206°C/W
206°C/W
140°C/W
149°C/W
NOTE 2: Maximum power dissipation is a function of TJ(max),
θ
JA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) − TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
recommended operating conditions
MIN
VKA
IKA
TA
Cathode voltage
Cathode current
TL43xxC
Operating free-air temperature range
TL43xxI
TL43xxQ
Vref
1
0
−40
−40
MAX
36
100
70
85
125
°C
C
UNIT
V
mA
POST OFFICE BOX 655303
•
DALLAS, TEXAS 75265
11