www.ti.com
......................................................................................................................................................................................................
SLOS559 – JUNE 2008
BACK-END ERROR (BKND_ERR)
Control signal parameters over recommended operating conditions (unless otherwise noted)
PARAMETER
t
w(ER)
t
p(valid_high)
t
p(valid_low)
Pulse duration, BKND_ERR active (active-low)
Time to stay in the OUT_x low state. After t
p(valid_high)
, the TAS5701 attempts to bring
the system out of the OUT_x low state if BKND_ERR is high.
Time TAS5701 takes to bring OUT_x low after BKND_ERR assertion.
t
w(ER)
MIN
350
TYP
300
350
MAX
UNIT
ns
ms
ns
BKND_ERR
VALID
Normal
Operation
t
p(valid_high)
t
p(valid_low)
Normal
Operation
T0031-04
Figure 7. Error Recovery Timing
MUTE TIMING (MUTE)
Control signal parameters over recommended operating conditions (unless otherwise noted)
PARAMETER
t
d(VOL)
(1)
Volume ramp time. Ramp time = Number of steps × stepsize
(1)
MIN
TYP
1024
MAX
UNIT
steps
Stepsize = 4 LRCLKs (for 32–48 kHz sample rate); 8 LRCLKs (for 88.2–96 kHz sample rate); 16 LRCLKs (for 176.4–192 kHz sample
rate)
MUTE
VOLUME
Normal
Operation
Normal
Operation
t
d(VOL)
50-50
Duty Cycle
t
d(VOL)
T0032-03
Figure 8. Mute Timing
Copyright © 2008, Texas Instruments Incorporated
Product Folder Link(s):