SN54LVC14A, SN74LVC14A
HEX SCHMITT-TRIGGER INVERTERS
SCAS285X – MARCH 1993 – REVISED JULY 2005
www.ti.com
Switching Characteristics
over operating free-air temperature range (unless otherwise noted) (see Figure 1)
SN54LVC14A
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
2.7 V
3.3 V
±
0.3 V
1
–55 TO 125°C
MIN
t
pd
A
Y
MAX
7.5
6.4
ns
UNIT
Switching Characteristics
over operating free-air temperature range (unless otherwise noted) (see
SN74LVC14A
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
V
CC
1.8 V
±
0.15 V
t
pd
A
Y
2.5 V
±
0.2 V
2.7 V
3.3 V
±
0.3 V
t
sk(o)
3.3 V
±
0.3 V
T
A
= 25°C
MIN
1
1
1
1
TYP
5
3.4
3.6
3.2
MAX
10.5
7.3
7.3
6.2
1
–40 TO 85°C
MIN
1
1
1
1
MAX
11
7.8
7.5
6.4
1
–40 TO 125°C
MIN
1
1
1
1
MAX
13
10
9.5
8
1.5
ns
ns
UNIT
Operating Characteristics
T
A
= 25°C
PARAMETER
TEST
CONDITIONS
f = 10 MHz
V
CC
1.8 V
C
pd
Power dissipation capacitance per inverter
2.5 V
3.3 V
TYP
11
12
15
pF
UNIT
6