SN74LVC1G04
SINGLE INVERTER GATE
www.ti.com
SCES214S–APRIL 1999–REVISED OCTOBER 2005
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
MIN
–0.5
–0.5
–0.5
MAX
6.5
UNIT
V
VCC
VI
Supply voltage range
Input voltage range
6.5
V
VO
VO
IIK
Voltage range applied to any output in the high-impedance or power-off state(2)
Voltage range applied to any output in the high or low state(2)(3)
6.5
V
–0.5 VCC + 0.5
V
Input clamp current
VI < 0
–50
–50
±50
±100
206
252
142
154
132
TBD
mA
mA
mA
mA
IOK
IO
Output clamp current
VO < 0
Continuous output current
Continuous current through VCC or GND
DBV package
DCK package
DRL package
θJA
Package thermal impedance(4)
°C/W
°C
YEA/YZA package
YEP/YZP package
YZV package
Tstg
Storage temperature range
–65
150
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output negative-voltage ratings may be exceeded if the input and output current ratings are observed.
(3) The value of VCC is provided in the recommended operating conditions table.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.