www.ti.com
SINGLE 2-INPUT POSITIVE-AND GATE
SCES217T – APRIL 1999 – REVISED FEBRUARY 2007
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN
V
CC
V
I
V
O
V
O
I
IK
I
OK
I
O
Supply voltage range
Input voltage range
(2)
Voltage range applied to any output in the high-impedance or power-off state
(2)
Voltage range applied to any output in the high or low
Input clamp current
Output clamp current
Continuous ouput current
Continuous current through V
CC
or GND
DBV package
DCK package
θ
JA
Package thermal
impedance
(4)
DRL package
DRY package
YZP package
T
stg
(1)
(2)
(3)
(4)
Storage temperature range
–65
state
(2) (3)
V
I
< 0
V
O
< 0
–0.5
–0.5
–0.5
–0.5
MAX
6.5
6.5
6.5
V
CC
+ 0.5
–50
–50
±50
±100
206
252
142
234
132
150
°C
°C/W
UNIT
V
V
V
V
mA
mA
mA
mA
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input and output negative-voltage ratings may be exceeded if the input and output current ratings are observed.
The value of V
CC
is provided in the recommended operating conditions table.
The package thermal impedance is calculated in accordance with JESD 51-7.