SN54LVC138A, SN74LVC138A
3-LINE TO 8-LINE DECODERS/DEMULTIPLEXERS
SCAS291T – MARCH 1993 – REVISED JULY 2005
www.ti.com
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN
V
CC
V
I
V
O
I
IK
I
OK
I
O
Supply voltage range
Input voltage range
(2)
Output voltage range
(2) (3)
Input clamp current
Output clamp current
Continuous output current
Continuous current through V
CC
or GND
D package
(4)
DB package
(4)
DGV package
(4)
θ
JA
Package thermal impedance
GQN/ZQN
package
(4)
NS package
(4)
PW package
(4)
RGY package
(5)
T
stg
(1)
(2)
(3)
(4)
(5)
Storage temperature range
–65
V
I
< 0
V
O
< 0
–0.5
–0.5
–0.5
MAX
6.5
6.5
V
CC
+ 0.5
–50
–50
±50
±100
73
82
120
78
64
108
39
150
°C
°C/W
UNIT
V
V
V
mA
mA
mA
mA
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input and output negative-voltage ratings may be exceeded if the input and output current ratings are observed.
The value of V
CC
is provided in the recommended operating conditions table.
The package thermal impedance is calculated in accordance with JESD 51-7.
The package thermal impedance is calculated in accordance with JESD 51-5.