欢迎访问ic37.com |
会员登录 免费注册
发布采购

SN74AUC2G86DCURE4 参数 Datasheet PDF下载

SN74AUC2G86DCURE4图片预览
型号: SN74AUC2G86DCURE4
PDF下载: 下载PDF文件 查看货源
内容描述: 双2输入异或门 [DUAL 2-INPUT EXCLUSIVE-OR GATE]
分类和应用: 栅极触发器逻辑集成电路石英晶振光电二极管输入元件
文件页数/大小: 13 页 / 544 K
品牌: TI [ TEXAS INSTRUMENTS ]
 浏览型号SN74AUC2G86DCURE4的Datasheet PDF文件第1页浏览型号SN74AUC2G86DCURE4的Datasheet PDF文件第3页浏览型号SN74AUC2G86DCURE4的Datasheet PDF文件第4页浏览型号SN74AUC2G86DCURE4的Datasheet PDF文件第5页浏览型号SN74AUC2G86DCURE4的Datasheet PDF文件第6页浏览型号SN74AUC2G86DCURE4的Datasheet PDF文件第7页浏览型号SN74AUC2G86DCURE4的Datasheet PDF文件第8页浏览型号SN74AUC2G86DCURE4的Datasheet PDF文件第9页  
DUAL 2-INPUT EXCLUSIVE-OR GATE
SCES479B – AUGUST 2003 – REVISED JANUARY 2007
www.ti.com
FUNCTION TABLE
(each gate)
INPUTS
A
L
L
H
H
B
L
H
L
H
OUTPUT
Y
L
H
H
L
EXCLUSIVE-OR LOGIC
An exclusive-OR gate has many applications, some of which can be represented better by alternative logic
symbols.
EXCLUSIVE OR
=1
These are five equivalent exclusive-OR symbols valid for an SN74AUC2G86 gate in positive logic; negation may be shown at any two ports.
LOGIC-IDENTITY ELEMENT
=
EVEN-PARITY ELEMENT
2k
ODD-PARITY ELEMENT
2k + 1
The output is active (low) if
all inputs stand at the same
logic level (i.e., A = B).
The output is active (low) if
an even number of inputs
(i.e., 0 or 2) are active.
The output is active (high) if
an odd number of inputs
(i.e., only 1 of the 2) are
active.
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN
V
CC
V
I
V
O
V
O
I
IK
I
OK
I
O
Supply voltage range
Input voltage range
(2)
Voltage range applied to any output in the high-impedance or power-off state
(2)
Output voltage range
(2)
Input clamp current
Output clamp current
Continuous output current
Continuous current through V
CC
or GND
DCT package
θ
JA
T
stg
(1)
(2)
(3)
Package thermal impedance
(3)
Storage temperature range
DCU package
YZP package
–65
V
I
< 0
V
O
< 0
–0.5
–0.5
–0.5
–0.5
MAX
3.6
3.6
3.6
V
CC
+ 0.5
–50
–50
±20
±100
220
227
102
150
°C
°C/W
UNIT
V
V
V
V
mA
mA
mA
mA
Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.
The package thermal impedance is calculated in accordance with JESD 51-7.