ꢀ ꢁꢂꢃ ꢃꢄ
ꢅ ꢆꢇꢈ ꢉꢊꢋ ꢊꢀ ꢇ ꢈꢌꢍ ꢆꢀ ꢍꢎ ꢏ ꢊ ꢎ ꢍꢊ ꢀꢇꢐꢑ ꢎ ꢋꢇꢈ ꢇꢒ ꢍꢈ ꢑꢓ ꢑꢊ ꢀ
SLOS073D − MARCH 1976 − REVISED SEPTEMBER 2004
schematic (each amplifier)
V
CC+
IN−
IN+
OUT
V
CC−
†
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage (see Note 1): V
V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −18 V
CC+
CC−
Differential input voltage, V (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 V
ID
Input voltage, V (any input, see Notes 1 and 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 V
I
Duration of output short circuit to ground, one amplifier at a time (see Note 4) . . . . . . . . . . . . . . . . . Unlimited
Package thermal impedance, θ (see Notes 5 and 6): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W
JA
DGK package . . . . . . . . . . . . . . . . . . . . . . . . 172°C/W
P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85°C/W
PS package . . . . . . . . . . . . . . . . . . . . . . . . . . . 95°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . 149°C/W
Operating virtual junction temperature, T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
J
Storage temperature range, T
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between V
2. Differential voltages are at IN+ with respect to IN−.
and V .
CC−
CC+
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. Temperature and/or supply voltages must be limited to ensure that the dissipation rating is not exceeded.
5. Maximum power dissipation is a function of T (max), θ , and T . The maximum allowable power dissipation at any allowable
J
JA
A
ambient temperature is P = (T (max) − T )/θ . Operating at the absolute maximum T of 150°C can affect reliability.
D
J
A
JA
J
6. The package thermal impedance is calculated in accordance with JESD 51-7.
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265