 浏览型号PCA9555PW的Datasheet PDF文件第9页浏览型号PCA9555PW的Datasheet PDF文件第10页浏览型号PCA9555PW的Datasheet PDF文件第11页浏览型号PCA9555PW的Datasheet PDF文件第12页浏览型号PCA9555PW的Datasheet PDF文件第14页浏览型号PCA9555PW的Datasheet PDF文件第15页浏览型号PCA9555PW的Datasheet PDF文件第16页浏览型号PCA9555PW的Datasheet PDF文件第17页  
PCA9555  
REMOTE 16-BIT I2C AND SMBus I/O EXPANDER  
WITH INTERRUPT OUTPUT AND CONFIGURATION REGISTERS  
www.ti.com  
SCPS131DAUGUST 2005REVISED OCTOBER 2006  
Absolute Maximum Ratings(1)  
over operating free-air temperature range (unless otherwise noted)  
MIN  
–0.5  
–0.5  
–0.5  
MAX  
6
UNIT  
V
VCC  
VI  
Supply voltage range  
Input voltage range(2)  
Output voltage range(2)  
6
V
VO  
IIK  
6
V
Input clamp current  
VI < 0  
–20  
–20  
±20  
50  
mA  
mA  
mA  
mA  
mA  
IOK  
IIOK  
IOL  
IOH  
Output clamp current  
VO < 0  
Input/output clamp current  
Continuous output low current  
Continuous output high current  
Continuous current through GND  
Continuous current through VCC  
VO < 0 or VO > VCC  
VO = 0 to VCC  
VO = 0 to VCC  
–50  
–200  
160  
63  
ICC  
mA  
DB package  
DBQ package  
DGV package  
DW package  
PW package  
RGE package  
RGE package  
61  
86  
θJA  
Package thermal impedance, junction to free air(3)  
°C/W  
46  
88  
45  
θJP  
Package thermal impedance, junction to pad  
Storage temperature range  
1.5  
150  
°C/W  
°C  
Tstg  
–65  
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings  
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating  
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
(2) The input negative-voltage and output voltage ratings may be exceeded if the input and output current ratings are observed.  
(3) The package thermal impedance is calculated in accordance with JESD 51-7.  
Recommended Operating Conditions  
MIN  
2.3  
MAX  
5.5  
UNIT  
VCC  
VIH  
Supply voltage  
V
SCL, SDA  
0.7 × VCC  
0.7 × VCC  
–0.5  
5.5  
High-level input voltage  
V
V
A2–A0, P07–P00, P17–P10  
SCL, SDA  
5.5  
0.3 × VCC  
0.3 × VCC  
–10  
VIL  
Low-level input voltage  
A2–A0, P07–P00, P17–P10  
P07–P00, P17–P10  
P07–P00, P17–P10  
–0.5  
IOH  
IOL  
TA  
High-level output current  
Low-level output current  
Operating free-air temperature  
mA  
mA  
°C  
25  
–40  
85  
13  