NA555, NE555, SA555, SE555
PRECISION TIMERS
www.ti.com
SLFS022F–SEPTEMBER 1973–REVISED JUNE 2006
Operating Characteristics
VCC = 5 V to 15 V, TA = 25°C (unless otherwise noted)
NA555
NE555
SA555
SE555
TYP
TEST
PARAMETER
UNIT
CONDITIONS(1)
MIN
MAX
MIN
TYP
1
MAX
Each timer, monostable(3)
Initial error of timing
TA = 25°C
0.5 1.5(4)
3
%
interval(2)
Each timer, astable(5)
Each timer, monostable(3)
Each timer, astable(5)
Each timer, monostable(3)
Each timer, astable(5)
1.5
2.25
50
TA = MIN to MAX
TA = 25°C
30 100(4)
90
0.05 0.2(4)
Temperature coefficient of
timing interval
ppm/
°C
150
0.1
0.3
0.5
Supply-voltage sensitivity of
timing interval
%/V
0.15
CL = 15 pF,
TA = 25°C
Output-pulse rise time
Output-pulse fall time
100 200(4)
100 200(4)
100
100
300
300
ns
ns
CL = 15 pF,
TA = 25°C
(1) For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
(2) Timing interval error is defined as the difference between the measured value and the average value of a random sample from each
process run.
(3) Values specified are for a device in a monostable circuit similar to Figure 9, with the following component values: RA = 2 kΩ to 100 kΩ,
C = 0.1 µF.
(4) On products compliant to MIL-PRF-38535, this parameter is not production tested.
(5) Values specified are for a device in an astable circuit similar to Figure 12, with the following component values: RA = 1 kΩ to 100 kΩ,
C = 0.1 µF.
6
Submit Documentation Feedback