MC3303, MC3403
QUADRUPLE LOW-POWER OPERATIONAL AMPLIFIERS
SLOS101C – FEBRUARY 1979 – REVISED FEBRUARY 2002
electrical characteristics, V
= 5 V, V
= 0 V, T = 25°C (unless otherwise noted)
CC– A
CC+
MC3303
MC3403
TYP
2
†
PARAMETER
TEST CONDITIONS
UNIT
MIN
TYP
MAX
10
MIN
MAX
10
V
IO
Input offset voltage
Input offset current
Input bias current
V
V
V
= 2.5 V
= 2.5 V
= 2.5 V
= 10 kΩ
= 10 kΩ,
mV
nA
µA
O
O
O
I
I
75
30
50
IO
–0.5
–0.2
3.5
–0.5
IB
R
3.3
3.5
3.3
L
‡
V
OM
Peak output voltage swing
V
R
V
V
CC+
– 1.7
L
CC+
– 1.7
V
V
= 5 V to 30 V
CC+
Large-signal
A
VD
= 1.7 V to 3.3 V, R = 2 kΩ
20
200
20
200
V/mV
O
L
differential voltage amplification
Supply-voltage sensitivity
k
V
V
= ±2.5 V to ±15 V
150
7
150
7
µV/V
SVS
CC±
(∆V /∆V
)
IO CC±
I
Supply current
= 2.5 V, No load
2.5
2.5
mA
dB
CC
O
V
V
Crosstalk attenuation
f = 1 kHZ to 20 kHZ
120
120
O1/ O2
†
‡
All characteristics are measured under open-loop conditions with zero common-mode input voltage unless otherwise specified.
Output will swing essentially to ground.
operating characteristics, V
= 14 V, V
= 0 V for MC3303, V
= ±15 V for MC3403,
±
CC+
CC–
CC
T = 25°C, A = 1 (unless otherwise noted)
A
VD
PARAMETER
Slew rate at unity gain
Rise time
TEST CONDITIONS
TYP
0.6
0.35
0.35
20
UNIT
V/µs
µs
SR
V = ±10 V,
C
C
C
C
= 100 pF,
= 100 pF,
= 100 pF,
= 100 pF,
R
R
R
R
= 2 kΩ,
See Figure 1
See Figure 1
See Figure 1
See Figure 1
I
L
L
L
L
L
t
∆V = 50 mV,
= 10 kΩ,
= 10 kΩ,
= 10 kΩ,
r
f
O
L
t
Fall time
∆V = 50 mV,
µs
O
L
Overshoot factor
Crossover distortion
∆V = 50 mV,
%
O
L
V
I(PP)
= 30 mV,
V
OPP
= 2 V,
f = 10 kHZ
1
%
PARAMETER MEASUREMENT INFORMATION
–
OUT
+
V
I
R
L
C
= 100 pF
L
Figure 1. Unity-Gain Amplifier
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265